NSN 5996-01-502-1375 NIIN 015021375 — Electronic Control Amplifier

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5996-01-502-1375
5996015021375
Description:
AMPLIFIER,ELECTRONIC CONTROL
NSN Assigned:
28-OCT-02
DEMIL:
 DEMIL
Shelf Life:
N/A
UOM:
No qup EA
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5996-01-502-1375 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

12.000in. ⁓12-1/64"

Overall Height ABKW:

5.500in.

Overall Width ABMK:

4.500in.

Environmental Protection ADZC:

watertight

Individual Section Quantity AFBH:

1

Shock Resistance Rating In Gravitational Units AFDP:

15.0

Average Life Measurement AFSU:

not rated

End Item Identification AGAV:

an/TSQ-131 (v) control and comm subsys

Basic Shape Style AGTA:

rectangular or square

Inclosure Type AKNA:

encased

Installation Design AMQY:

portable

Circuit Construction Type BHSX:

solid state

Frequency Per Channel BHTB:

Average Power Rating Per Channel BHTJ:

40.0 watts output

Signal Data Type Per Channel BHTZ:

operating channel radio frequency

Features Provided CBBL:

internal battery accommodation

Part Name Assigned By Controlling Agency CXCY:

inavy: uhf satcom power amp; cage: 40 watt satcom tranportable amp, configured for operation with ARC-210 (added external rx connector)

Special Features FEAT:

configured for operation with ARC-210 (added external rx connector) ; CASE-Transportable; 40 watts of rf output power into a 2:1 vswr load under alltemp. and load conditions; also amplifies rf signals from a satellite antenna in the receive direction; internal transmit/receive switch; dc/dc power supply; automatic/manual los bypass mode; pa/PRE-Amplifier is remotable to 300 ft via a single coaxial connection; accomodates all psk/fsk moculation techniquis and tdma/dama formats

Supplementary Features SUPP:

includes ac/dc power supply: 8 in. w x 2.6 in h x 2.6 h x 11 d) and remote control unit (3.6 in w x 5.0 h x 2.8 d) that allows operator control of output power levels, receive power levels, satcom/los control and displays rcu and amp status and operating time; remote powered by either 28 vdc MIL-STD-1275A or 110/220 vac universal power source

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
25000-3
Cage Code:
06GW1
RNCC:
3
RNVC:
2
DAC:
3
RNAAC:
HD
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00096
FIIG:
A32200
Concept No.:
App. Key:
C
Cond. Code:
1
Status:
A
BASIC SHAPE STYLE RECTANGULAR OR SQUARE style nsn 5996-01-502-1375

Definition Definition of approved item name (AIN): "AMPLIFIER,ELECTRONIC CONTROL"

An electronic device which enables input signals to control a local source of power and deliver output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals, and are suitable for controlling or supplying power for exciting electric motors or similar devices. It includes devices commonly referred to as servo amplifiers, torque amplifiers and similar equipment only if these devices do not employ synchros nor incorporate servomechanisms. It does not include items which are properly classified as audio frequency, radio frequency, direct current or video amplifiers. For amplifiers that incorporate servomechanisms and employ synchros, see amplifier, synchro signal.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
03
LVL_A:
E
LVL_B:
F
LVL_C:
F
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) F

Packing is not required. the unit container shall also serve as the shipping container. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 03

Method 50.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5996-01-502-1375 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
A
ESD:
A
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Electrostatic Discharge (ESD) A

No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
NRP
SOS:
MMAC:
MCC:
Source of Supply (SOS) NRP

Navicp-erp 700 robbins avenue philadelphia, pa 19111-5099

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.