Serving our customers with quality and safety first.
aluminum
21.240in. ⁓21-1/4"
3.500in.
18.240in.
+0.0/+50.0 deg celsius
0.733 cubic feet
not rated
rectangular or square
10000.0 feet
encased
manual
top of cabinet/counter and rack
local
solid state
10.0 watts output
30.0 decibels
receptacle, coaxial front
47.0 single voltage and 63.0 single voltage
250.0 watts
1 receptacle, coaxial internal
99.0 single voltage and 132.0 single voltage
single
front panel controls: prime power on/off, rf operate/standby (fault reset) . front panel indicators: prime power on/standby, rf operate, fault. metering: helix current. protection: prime power fuse, warm up delay, automatic sequencing of high voltage and beam current, unattended protection (heater shutdown after fault counter trip) , helix current overload, high temperature low/high line voltage, safety interlocks. equipment case, is a SELF-Contained designed for bench top or rack mount. auto recycle if power outage is lessthan 3 seconds. automatic turn off if two consecutive helix overload faults occur:noise figure 35db max: spurious modulation M50Dbc max: load vswr 2.5:1 max: gain stability 0.25db/24hrs: maxoperating humidity 95pct
6625010346118
An electronic device whose radio frequency input signals control power from a source independent of the input signals, and delivers radio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies above 20 kilohertz.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Item does not contain precious metal.
No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.