NSN 5990-00-021-5061 NIIN 000215061 — Control Transformer Synchro

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5990-00-021-5061
5990000215061
Description:
SYNCHRO,CONTROL TRANSFORMER
NSN Assigned:
02-MAY-67
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5990-00-021-5061 Specification Set by the OEM (see RNCC code 3)

Body Material AAFZ:

any acceptable

Body Style AAQL:

standard round a

Pilot Diameter AAVL:

0.4995in. and 0.5000in.

Overall Length ABHP:

1.5980in. and 1.6280in. ⁓1-41/64"

Flange Diameter ABKK:

0.7470in. and 0.7500in.

Flange Thickness ABKU:

0.0620in.

Undercut Diameter ABPA:

0.6910in.

Undercut Width ABPC:

0.0570in.

Shaft Diameter ABWV:

0.0895in. single shaft and 0.0900in. single shaft

Shaft Length ABXF:

0.3170in. single shaft and 0.3470in. single shaft

Maximum Temp Rise AHCG:

6.0 deg celsius

Body Size AJSL:

8

Stator Input Voltage Rating In Volts AJSN:

11.7 and 11.9

Stator Input Current Rating AJSP:

43.0 milliamperes

Stator Input Electrical Power Rating AJSQ:

120.0 milliwatts

Frequency In Hertz AJSS:

400.0

Zro Resistance In Ohms AJSW:

340.00 and 460.00

Zso Resistance In Ohms AJSY:

51.00 and 69.00

Zrs Resistance In Ohms AJTA:

692.00

Rotor Dc Resistance In Ohms AJTS:

328.50 and 401.50

Stator Dc Resistance In Ohms AJTT:

57.60 and 70.40

Phase Shift Angle In Deg AJVF:

10.500 input to output

Maximum Fundamental Null Voltage In Millivolts Per Volt AJVG:

30.00 output

Maximum Total Null Voltage Output In Millivolts Per Volt AJVH:

10.50

Electrical Error Angular Range In Minutes AJVL:

-5.0/+5.0

Actuator Friction Torque At Minus 55 Deg Celsius AJVS:

9.00 INCH-Ounces

Actuator Friction Torque At Plus 25 Deg Celsius AJVT:

3.00 INCH-Ounces

Pilot Length AJWQ:

0.0400in.

Mounting Surface To Terminal End Distance AJWX:

1.2410in.

Terminal Location CQTM:

rear

Plus J Zro Reactance In Ohms CQXQ:

1207.00 and 1633.00

Shaft Slot Depth CQZS:

0.0250in. single shaft

Plus J Zso Reactance In Ohms CRGZ:

216.00 and 292.00

Shaft Slot Width CRHN:

0.0200in. single shaft

Plus J Zrs Reactance In Ohms CRKL:

127.50 and 172.50

Shaft Type CRSJ:

round, slotted single shaft

Transformation Ratio CSJY:

127.500 rotor to stator and 172.500 rotor to stator

Terminal Type And Quantity TTQY:

5 wire lead

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
142739-01
Cage Code:
35351
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
KE
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
15289
FIIG:
A07800
Concept No.:
1
App. Key:
B
Cond. Code:
1
Status:
A
BODY STYLE STANDARD ROUND A style nsn 5990-00-021-5061

Definition Definition of approved item name (AIN): "SYNCHRO,CONTROL TRANSFORMER"

A synchro consisting of a stator and rotor inductively coupled. The electrical output of the rotor is dependent upon both the position of the rotor and the electrical input to the stator from a transmitter synchro or a differential synchro. Does not include variable resistors, goniometers, or variable transformers.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.2000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
U

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5990-00-021-5061 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.