NSN 5985-01-613-1897 NIIN 016131897 — Radio Frequency Transmissio Line

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5985-01-613-1897
5985016131897
Description:
LINE,RADIO FREQUENCY TRANSMISSIO
NSN Assigned:
01-NOV-12
DEMIL:
 DEMIL
Shelf Life:
N/A
UOM:
No qup EA
Using Services:
Air Force

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5985-01-613-1897 Specification Set by the OEM (see RNCC code 3)

Overall Length AAJU:

48.0in.

End Item Identification AGAV:

4920-01-327-4741

Characteristic Impedance In Ohms AJDD:

50.0

Termination Identification AJDF:

MIL-PRF-39012

Conductor Quantity AMQN:

2

Outer Conductor APZC:

included

Insulation Spacer Shape APZD:

cylindrical

Termination Controlling Agency AQBB:

military

Terminal Fitting AQBD:

included

Accommodated Conductor Type AQCE:

coaxial

Part Name Assigned By Controlling Agency CXCY:

cable assembly, r.f.

Special Features FEAT:

armor shall provide 300 lb per linier inch.

Security Classification SECL:

unclassified

Supplementary Features SUPP:

mateing torque 12-15 in/lbs; type N-Plug male right angle; center contact beryllium copper, gold plated.

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
6014491-005
Cage Code:
12436
RNCC:
3
RNVC:
2
DAC:
E
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
R90-2748-005
Cage Code:
57500
RNCC:
3
RNVC:
2
DAC:
E
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00884
FIIG:
T224-E
Concept No.:
App. Key:
EA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "LINE,RADIO FREQUENCY TRANSMISSIO"

An item designed primarily for the conduction of radio frequency energy, and consisting of two or more conductors supported in fixed spatial relationship(s) along their own length. Since the characteristic impedance of the line is determined by the spatial relationships of the conductors, which are sufficiently rigid to maintain these relationships between supports, the configuration of the item is usually not susceptible to mechanical manipulation; that is, it is not normally flexible. Includes a single conductor inclosed in an outer concentric conductor (coaxial) or two or more conductors laid parallel. All types have low loss or special characteristics at high frequencies. May include fittings or terminations. For items having continuous homogeneous dielectric, see cable, radio frequency. See also line section, radio frequency transmission.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
E
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5985-01-613-1897 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
A
ESD:
A
ADPE:
0
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

Electrostatic Discharge (ESD) A

No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.