50.0
50.000 kilowatts average
connector
forced liquid
fac power requirements 230 vac, single phase 27.5 amp; 208-230/460 vac, three phase 9.6/4.8 amp; finish beige splatter; fan 1.5 hp centrifugal; pump 1.5 hp centrifugal; vswr 60 hz to 800mhz 1.1:1 max
model 5850 rf heat exchanger is a model 9750 50 ohm resistor assembly cooled by a vented, CLOSED-Loop water system, utilizing a centrifugal pump, WATER-TO-Air heat exchanger, capacity of coolant is approx 11 us gallons, and 1 centrifugal blower; blower assy is a 1.5 hp BELT-Driven centrifugal blower, blower moves air into a closed plenum, through the heat exchanger coil to the rear of unit
location should be dry, free of excessive dust and ambient temp P5.0 to 35 deg c with water only and M20.0 to 30.0 deg c with porm 35 pct ethylene glycol mixture; room well ventilated; rf dissipation of unit is 50, 000 watts equals 170.650 btu/hr usually ducted out of building; not necessary to mount which is designed to be a FREE-Standing device resting on 4 heavy duty casters; brakes are installed on swivel casters; 4 terminal, CAPTIVE-Screw terminal strip
A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also load bank, electrical.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item does not contain precious metal.
No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.