NSN 5970-00-998-2800 NIIN 009982800 — Electric Insulating Compound Kit

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5970-00-998-2800
5970009982800
Description:
INSULATING COMPOUND KIT,ELECTRIC
NSN Assigned:
20-APR-67
DEMIL:
NO
Shelf Life:
18 months
UOM:
No qup KT
Using Services:
Navy, Coast Guard, Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5970-00-998-2800 Specification Set by the OEM (see RNCC code 3)

Storage Temp Range AFJQ:

-7.0/+77.0 deg celsius

Component Quantity AJJW:

2

Component Document Origin AJJX:

industrial

Document Source AJJY:

04347

Document Type AJJZ:

mfr bulletin

Component Document Page Number AJKB:

1

Container Type ALQG:

can

Document Identification AYDR:

elecreical insulation materials bulletin E4-211C

Unpackaged Unit Weight PKWT:

4.050 pounds

Nondefinitive Spec/std Data ZZZT:

er type

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
MIL-I-46058
Cage Code:
81349
RNCC:
4
RNVC:
1
DAC:
3
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
PC16
Cage Code:
04347
RNCC:
C
RNVC:
1
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
HYSOL PC12-007 1QTKT
Cage Code:
04347
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
93003
Cage Code:
94117
RNCC:
5
RNVC:
2
DAC:
1
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
HYSOL PC12-007M
Cage Code:
04347
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
PC12-007M
Cage Code:
04347
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
PC12-007A-PC12-007B
Cage Code:
04347
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
CX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
32318
FIIG:
A23800
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "INSULATING COMPOUND KIT,ELECTRIC"

A collection of two or more separate chemical materials which, when mixed, forms an electrical insulating composition prior to usage, or when applied. It is usually composed of liquid, paste, crystal, or solid forms with curing agents, or the like. For pre-mixed electrical insulating items, see insulating compound, electrical. For items not specifically compounded for electrical insulating, see sealing compound. Excludes insulating oil, electrical and insulating varnish, electrical.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
3.5000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
32
LVL_A:
E
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 32

Type i, shelf life.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5970-00-998-2800 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
Y
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) Y

Indicates information is in the hazardous materials information resource system (hmirs).

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.