NSN 5970-00-221-5316 NIIN 002215316 — Electrical Insulation Sleeving

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5970-00-221-5316
5970002215316
Description:
INSULATION SLEEVING,ELECTRICAL
NSN Assigned:
01-JAN-63
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5970-00-221-5316 Specification Set by the OEM (see RNCC code 3)

Wall Thickness AAGT:

0.013in. and 0.019in.

Reliability Indicator AARG:

not established

Inside Diameter AARX:

0.091in. and 0.101in.

Temp Rating ABJH:

-30.0 deg celsius and 75.0 deg celsius

Heat Shrinkage Rating In Percent AGAU:

10.0

Special Features FEAT:

800 v test per mil of thk

Flexibility FLEX:

flexible

Color HUES:

clear

Material MATL:

plastic, polyvinyl chloride, MIL-I-631, type f, form u, subform ua, grade c, class 1

Material MATT:

plastic polyvinyl chloride

Style Designator STYL:

nonshrinkable

Nondefinitive Spec/std Data ZZZT:

f type and a grade and 2 class and 11 size and u form and ua subform and 1 category

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
NATVAR 400/461
Cage Code:
96904
RNCC:
3
RNVC:
1
DAC:
4
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
MILI631
Cage Code:
81349
RNCC:
4
RNVC:
1
DAC:
4
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
FLEXITE HT-105C
Cage Code:
03890
RNCC:
5
RNVC:
1
DAC:
3
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
ITCO 929
Cage Code:
12509
RNCC:
5
RNVC:
1
DAC:
5
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
ASTRA 703/105
Cage Code:
91094
RNCC:
5
RNVC:
1
DAC:
3
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
740040-11
Cage Code:
80045
RNCC:
3
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
TEMFLEX 105C 11 AWG CLEAR
Cage Code:
76381
RNCC:
5
RNVC:
9
DAC:
3
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
TEMFLEX 105C 11 AWG CLEAR
Cage Code:
20999
RNCC:
5
RNVC:
9
DAC:
3
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
TEMFLEX 105C 11 AWG CLEAR
Cage Code:
75037
RNCC:
5
RNVC:
9
DAC:
3
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
3003
Cage Code:
20999
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
3003
Cage Code:
75037
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
GS830L-11C
Cage Code:
26512
RNCC:
5
RNVC:
9
DAC:
A
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
NATVAR 400/461
Cage Code:
96904
RNCC:
3
RNVC:
1
DAC:
4
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
MILI631
Cage Code:
81349
RNCC:
4
RNVC:
1
DAC:
4
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
FLEXITE HT-105C
Cage Code:
03890
RNCC:
5
RNVC:
1
DAC:
3
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
ITCO 929
Cage Code:
12509
RNCC:
5
RNVC:
1
DAC:
5
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
ASTRA 703/105
Cage Code:
91094
RNCC:
5
RNVC:
1
DAC:
3
RNAAC:
CX
Status:
F
MSDS:
SADC:
Part Number:
740040-11
Cage Code:
80045
RNCC:
3
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
GS830L-11C
Cage Code:
26512
RNCC:
5
RNVC:
9
DAC:
A
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
TEMFLEX 105C 11 AWG CLEAR
Cage Code:
20999
RNCC:
5
RNVC:
9
DAC:
3
RNAAC:
CX
Status:
R
MSDS:
SADC:
Part Number:
TEMFLEX 105C 11 AWG CLEAR
Cage Code:
75037
RNCC:
5
RNVC:
9
DAC:
3
RNAAC:
CX
Status:
R
MSDS:
SADC:
Part Number:
3003
Cage Code:
75037
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
CX
Status:
R
MSDS:
SADC:
Part Number:
3003
Cage Code:
20999
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
CX
Status:
R
MSDS:
SADC:
Part Number:
TEMFLEX 105C 11 AWG CLEAR
Cage Code:
76381
RNCC:
5
RNVC:
9
DAC:
3
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
NATVAR 400/461
Cage Code:
96904
RNCC:
3
RNVC:
1
DAC:
4
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
MILI631
Cage Code:
81349
RNCC:
4
RNVC:
1
DAC:
4
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
FLEXITE HT-105C
Cage Code:
03890
RNCC:
5
RNVC:
1
DAC:
3
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
ITCO 929
Cage Code:
12509
RNCC:
5
RNVC:
1
DAC:
5
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
ASTRA 703/105
Cage Code:
91094
RNCC:
5
RNVC:
1
DAC:
3
RNAAC:
CX
Status:
F
MSDS:
SADC:
Part Number:
740040-11
Cage Code:
80045
RNCC:
3
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
GS830L-11C
Cage Code:
26512
RNCC:
5
RNVC:
9
DAC:
A
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
TEMFLEX 105C 11 AWG CLEAR
Cage Code:
20999
RNCC:
5
RNVC:
9
DAC:
3
RNAAC:
CX
Status:
R
MSDS:
SADC:
Part Number:
TEMFLEX 105C 11 AWG CLEAR
Cage Code:
75037
RNCC:
5
RNVC:
9
DAC:
3
RNAAC:
CX
Status:
R
MSDS:
SADC:
Part Number:
3003
Cage Code:
20999
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
CX
Status:
R
MSDS:
SADC:
Part Number:
3003
Cage Code:
75037
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
CX
Status:
R
MSDS:
SADC:
Part Number:
TEMFLEX 105C 11 AWG CLEAR
Cage Code:
76381
RNCC:
5
RNVC:
9
DAC:
3
RNAAC:
CX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00867
FIIG:
A22500
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A
STYLE DESIGNATOR NONSHRINKABLE style nsn 5970-00-221-5316

Definition Definition of approved item name (AIN): "INSULATION SLEEVING,ELECTRICAL"

A rigid or flexible tubing having uniform inside and outside diameters in the overall length. It is specifically designed to prevent any undesirable flow of current between conductors and other objects. Includes shrinkable type tubing, items in bulk and in specific fabricated lengths (cut to size). Excludes items not having rated electrical characteristics. Also excludes bushing, sleeve; cable nipple, electrical; conduit (as modified); insulation sleeving, electrical, special purpose; insulation sleeving, thermal; sleeve, marker, cable; sleeving, textile, electrical; tubing, glass; and tubing, nonmetallic.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
SPI No.:
SPI Rev.:
SPC Mkg:
99
LVL_A:
E
LVL_B:
Q
LVL_C:
U

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5970-00-221-5316 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.