NSN 5970-00-012-1276 NIIN 000121276 — Insulation Electrical Tape

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5970-00-012-1276
5970000121276
Description:
TAPE,INSULATION,ELECTRICAL
NSN Assigned:
10-MAY-68
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 RO
Using Services:
Navy
Description

Plastic basic material.

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5970-00-012-1276 Specification Set by the OEM (see RNCC code 3)

Nominal Overall Thickness CRZG:

0.085in.

Cut Type And Quantity CQNS:

1 single

Adhesive Type ALGP:

pressure sensitive

Nominal Length AKGG:

792in.

Nominal Width AKGF:

0.75in.

Dielectric Withstanding Voltage In Volts AAPB:

10000

Adhesive Location CSJX:

one side

Color HUES:

black

Material MATT:

plastic basic

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
88
Cage Code:
53387
RNCC:
C
RNVC:
1
DAC:
E
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
9F
Part Number:
88
Cage Code:
75037
RNCC:
3
RNVC:
9
DAC:
E
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
88
Cage Code:
76381
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
75
Status:
A
MSDS:
SADC:
Part Number:
SCOTCH 88 3/4 BY 66
Cage Code:
75037
RNCC:
5
RNVC:
9
DAC:
E
RNAAC:
CX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
33476
FIIG:
A14300
Concept No.:
App. Key:
B
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "TAPE,INSULATION,ELECTRICAL"

A narrow strip of woven or processed material less than twelve inches (304.8 mm) in width. It is specifically designed to prevent any undesirable flow of current between conductors and other objects. The item tends to resist any physical change, in contrast to an insulating compound in tape form which will fuse under a specified heat or pressure. It may or may not have adhesive backing. Excludes items not having definite rated electrical characteristics, such as tape, adhesive, rubber; tape, pressure sensitive adhesive; tape, semi-conducting, electrical; and tape, shielding, electrical. See also insulation cloth, electrical and insulating compound, electrical.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.1000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
SPI No.:
SPI Rev.:
SPC Mkg:
99
LVL_A:
E
LVL_B:
Q
LVL_C:
U

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5970-00-012-1276 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
S9G
SOS:
MMAC:
MCC:
Source of Supply (SOS) S9G

Defense supply center richmond, virginia 23297

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.