Serving our customers with quality and safety first.
0.358in.
0.358in.
0.100in.
1.0 watts
-55.0/+125.0 deg celsius
-65.0/+150.0 deg celsius
pacer dawn
hermetically sealed and burn in and programmable and positive outputs and electrostatic sensitive
ceramic and glass
leadless flat pack
TRANSISTOR-Transistor logic
16 input
cbbl
C-2 MIL-M-38510
solder
microcircuit, programmed (pal 16L8A)
-0.5 volts power source and 7.0 volts power source
30.00 nanoseconds propagation delay time, low to high level output and 30.00 nanoseconds propagation delay time, high to low level output
pal
altered item, made from device 81036072x, cage 67268
20 leadless
A circuit designed to store information and/or coded instructions for later use. Item has pins or other connections to install in a computer or computing device. does not include magnetic drums, tapes, punched cards or the like. for items that have portable type connections see memory, portable, solid state.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Item does not contain precious metal.
Represents items with esd sensitivity.
Represents items with no adp components
The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restrictions or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.