Serving our customers with quality and safety first.
1.188in. and 1.212in.
0.580in. and 0.600in.
0.066in. and 0.126in.
-55.0/+125.0 deg celsius
-65.0/+150.0 deg celsius
hermetically sealed and burn in and electrostatic sensitive and w/clock
ceramic
DUAL-IN-Line
TRANSISTOR-Transistor logic
19 input
1 converter, digital to analog
solder
-0.5 volts power source and 7.0 volts power source
35.00 nanoseconds propagation delay time, low to high level output and 35.00 nanoseconds propagation delay time, high to low level output
nuclear hardness critical items
hardened
96906-MIL-STD-883 standard (includes industry or association standards, individual manufactureer standards, etc.) .
24 printed circuit
A microcircuit having the dual functions of a microcircuit (1), digital and a microcircuit (1), linear.
Indicates that the item represented in the input/output header is the preferred replacement item master nsn in the i&s family and is suitable for the item(s)in segment h. use the item represented by the nsn in segment h if technically acceptable for your specific application. the replacement item, master nsn in the i&s family, will be issued when the supply of the replaced item(s) is exhausted. must be used in combination with phrase code f.
OOU: Order of Use. Three position alpha code denoting the interchangeability and substitutability (I&S) relationship of a national stock number within a service/agency I&S family.
JTC: Jump to Code. Three position alpha code that denotes an exception to the normal sequence to be followed in the attrition of items within an interchangeability and substitutability (I&S) family.
Phrase Code: A one position code assigned to a phrase used in the management data list to denote changes and/or relationships between national stock numbers and reference data.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Item does not contain precious metal.
Represents items with esd sensitivity.
Represents items with no adp components
The item is specifically designed to be or selected as being nuclear hard (i.e., it will continue to perform its designed function in an environment created by a nuclear explosion). the item does not have other critical features.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.