Operating Temperature Range: -55/+125 degrees Celsius, Body Height: 0.03 inches to 0.07 inches.
Serving our customers with quality and safety first.
gold
03640-6088492 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
0.24in. to 0.275in.
300 milliwatts
-55/+125 degrees celsius
0.03in. to 0.07in.
-65/+150 degrees celsius
0.24in. to 0.26in.
hermetically sealed and monolithic and high gain and adjustable and negative outputs and positive outputs
flat pack
ceramic and metal
up to 15 volts at power source
T0-86 joint electron device engineering council
5 input
1 amplifier, dc and 1 amplifier, wideband
50 nanoseconds propagation delay time, low to high level output and 50 nanoseconds propagation delay time, high to low level output
gold
terminals gold
14 flat leads
A microcircuit whose output is a function of the input; that is, the output varies in a predetermined and essentially predictable manner from the input signal.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 3.
All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.
Esd sensitive electronic device requirements of mil-std-129 apply.
OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.
SPI No.: Special packaging instructions number.
LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.
SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Item contains gold.
Represents items with esd sensitivity.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.
Defense logistics agency, enterprise business systems
General purpose automatic data processing equipment, software, supplies and support equipment
SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.
SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.
MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.
MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category
IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.