5961-00-006-9053
5961000069053
Description:
SEMICONDUCTOR DEVICE,DIODE
NSN Assigned:
30-JUN-72
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Marines, Navy, Army, Air Force
Description

Diameter: 0.009 inches to 0.145 inches, Voltage Rating In Volts Per Characteristic: 56 regulator voltage.

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5961-00-006-9053 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

0.14in. to 0.3in. ⁓5/16"

Terminal Type And Quantity TTQY:

2 uninsulated wire lead

Specification/standard Data ZZZK:

81349-MIL-S-19500/356 government specification

Mounting Method AXGY:

terminal

Inclosure Material ABBH:

glass

Terminal Length ABJT:

0.9in. to 1.5in.

Overall Diameter ADAV:

0.09in. to 0.145in. ⁓5/32"

Function For Which Designed AFZC:

zener diode

Semiconductor Material CTMZ:

silicon

Voltage Rating In Volts Per Characteristic CTQN:

56 regulator voltage

Current Rating Per Characteristic CTQX:

up to 84 milliamperes dc current in reverse breakdown region

Maximum Operating Temp Per Measurement Point CTSG:

175 degrees celsius ambient air

Power Rating Per Characteristic CTRD:

up to 5 watts total power dissipation

Voltage Tolerance In Percent CTQS:

-5 to 5

Test Data Document TEST:

81349-MIL-S-19500 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
JANTX1N4976
Cage Code:
81349
RNCC:
2
RNVC:
2
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
MIL-PRF-19500/356
Cage Code:
81349
RNCC:
4
RNVC:
1
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
UZ9299-23
Cage Code:
12969
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
848205-0023
Cage Code:
65597
RNCC:
5
RNVC:
1
DAC:
5
RNAAC:
48
Status:
A
MSDS:
SADC:
Part Number:
SS4533
Cage Code:
14099
RNCC:
5
RNVC:
1
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
JANTX1N4976
Cage Code:
C7191
RNCC:
5
RNVC:
1
DAC:
6
RNAAC:
ZG
Status:
A
MSDS:
SADC:
Part Number:
925115-23B
Cage Code:
82577
RNCC:
5
RNVC:
1
DAC:
A
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
1N4976
Cage Code:
07688
RNCC:
C
RNVC:
1
DAC:
6
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
196011P134
Cage Code:
94117
RNCC:
E
RNVC:
8
DAC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
405630-4
Cage Code:
49956
RNCC:
E
RNVC:
8
DAC:
5
RNAAC:
48
Status:
A
MSDS:
SADC:
Part Number:
152-0264-00
Cage Code:
80009
RNCC:
E
RNVC:
8
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
UZ756
Cage Code:
12969
RNCC:
E
RNVC:
8
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
DSZ2063
Cage Code:
01281
RNCC:
E
RNVC:
8
DAC:
5
RNAAC:
48
Status:
A
MSDS:
SADC:
Part Number:
MIL-S-19500/356
Cage Code:
81349
RNCC:
5
RNVC:
9
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
JAN1N4976
Cage Code:
81349
RNCC:
5
RNVC:
9
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
JANTX1N4976A
Cage Code:
C7191
RNCC:
5
RNVC:
9
DAC:
6
RNAAC:
ZG
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
20589
FIIG:
A110A0
Concept No.:
1
App. Key:
B
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "SEMICONDUCTOR DEVICE,DIODE"

A two electrode semiconductor device having an asymmetrical voltage - current characteristic. May or may not include mounting hardware and/or heatsink. Excludes light emitting diode and semiconductor device,photo. For items containing material such as selenium and copper oxide, see recifier, metallic.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.1000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Q
LVL_B:
Q
LVL_C:
6
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

LVL C Code (LVL_C) 6

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 3.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5961-00-006-9053 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
A
ESD:
A
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Electrostatic Discharge (ESD) A

No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
SMS
SOS:
MMAC:
EH
MCC:
SOS:
SMS
SOS:
MMAC:
MCC:
B2
Source of Supply (SOS) SMS

Defense logistics agency, enterprise business systems

Material Management (MMAC) EH

Electronic components (engineering support at the 88th ose/oss)

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.