NSN 5950-01-006-8605 NIIN 010068605 — Power Autotransforme Transformer

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5950-01-006-8605
5950010068605
Description:
TRANSFORMER,POWER AUTOTRANSFORME
NSN Assigned:
23-JUL-75
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy, Coast Guard

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5950-01-006-8605 Specification Set by the OEM (see RNCC code 3)

Reliability Indicator AARG:

not established

Center To Center Distance Between Mounting Facilities Parallel To Length ABKQ:

1.375in. single mounting facility single center group

Center To Center Distance Between Mounting Facilities Parallel To Width ABKR:

1.375in. single mounting facility single center group

Frequency Rating ACZB:

60.0 hertz single component

Input-output Phase Relationship ACZC:

single phase to single phase single component

Body Length ADAQ:

2.000in.

Body Width ADAT:

2.000in.

Body Height ADAU:

1.250in.

End Item Identification AGAV:

nimitz class cvn, wasp class lhd, oliver perry class ffg, arleigh burke burke class ddg, sturgeon class ssn (637) , ticonderoga class cg (47) , austin ship class LPD-4 amphibious transport docks, los angeles class ssn (688) , forrestal class cv, spruance class dd (963)

Inclosure Type AKNA:

fully inclosed

Mounting Facility Quantity AKPV:

4 single group

Mounting Method AXGY:

threaded stud single group

Winding Function And Quantity BPLC:

1 primary, fixed autotransformer type single component

Thread Quantity Per Inch CMLP:

32 single group

Nominal Thread Size CQJX:

0.138in. single group ⁓9/64"

Criticality Code Justification CRTL:

feat

Winding Operating Voltage CWJS:

3.00 ac volts single component single primary input

Special Features FEAT:

weapon system essential

Thread Series Designator THSD:

unc single group

Terminal Type And Quantity TTQY:

24 pin

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
403-3001 SD
Cage Code:
6Z539
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
0221C0072
Cage Code:
03538
RNCC:
C
RNVC:
1
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
9F
Part Number:
0221C0072
Cage Code:
54497
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
36166
FIIG:
A058B0
Concept No.:
1
App. Key:
M
Cond. Code:
2
Status:
A

Definition Definition of approved item name (AIN): "TRANSFORMER,POWER AUTOTRANSFORME"

A transformer which incorporates the primary and secondary functions into a single winding, which is common to both input and output circuits, and is designed to change the relationship of volts and amperes between the entire winding and its taps. Includes multiple winding transformers of like design and items in which a variation of the turns ratio or inductive ratio of inductive coupling is accomplished by connection to fixed terminals. Also, includes items having a provision for mechanically changing the turns ratio in progressive increments, by means of a shaft, voltage taps, ratio adjuster, or devices of similar design. Excludes transformer (1), power; transformer (1), pulse.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.6000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
U
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

LVL C Code (LVL_C) U

Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) postal regulations, (b) department of transportation regulations, (c) civil air regulations, (d) uniform freight classification rules, (e) national motor freight classification rules, (f) american truckers' association rules, (g) other applicable carriers' rules, (h) military air regulations for dangerous materials. consolidation of shipments. all exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. dangerous goods shall be prepared for shipment according to applicable department of transportation (dot) regulations and international regulations in effect at time of shipment. shipment by parcel post must comply with postal regulations.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5950-01-006-8605 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
Y
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality Y

The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restrictions or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Solicitation History DLA solicitations for NSN 5950-01-006-8605

Solicitation
Ends
Qty
AMSC
Buyer
PR
SMB
Solicitation:
SPE7MC15T9300
End Date:
05/04/2015
Qty:
7 Ea
AMSC:
L
Buyer Code:
PLCLX
PR:
0058188370
SMB:
100%