NSN 5950-00-230-7918 NIIN 002307918 — Reactor

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5950-00-230-7918
5950002307918
Description:
REACTOR
NSN Assigned:
24-OCT-70
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5950-00-230-7918 Specification Set by the OEM (see RNCC code 3)

Reliability Indicator AARG:

not established

Inductance Type ACYF:

fixed

Inductance Rating ACYV:

500.00 microhenries single component single winding

Body Length ADAQ:

0.300in.

Body Outside Diameter ADAR:

0.600in.

Winding Quantity AKDX:

1 single component

Inclosure Type AKNA:

open

Mounting Method AXGY:

terminal single group

Rating Method BKPL:

electrical single component single winding

Terminal Type And Quantity TTQY:

2 wire lead

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
95014-3
Cage Code:
04274
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00724
FIIG:
A058B0
Concept No.:
App. Key:
D
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "REACTOR"

A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes saturable reactor. For reactors with air cores, see coil (as modified).

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.1000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
U
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

LVL C Code (LVL_C) U

Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) postal regulations, (b) department of transportation regulations, (c) civil air regulations, (d) uniform freight classification rules, (e) national motor freight classification rules, (f) american truckers' association rules, (g) other applicable carriers' rules, (h) military air regulations for dangerous materials. consolidation of shipments. all exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. dangerous goods shall be prepared for shipment according to applicable department of transportation (dot) regulations and international regulations in effect at time of shipment. shipment by parcel post must comply with postal regulations.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5950-00-230-7918 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.