NSN 5945-01-196-2086 NIIN 011962086 — Electromagnetic Relay

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5945-01-196-2086
5945011962086
Description:
RELAY,ELECTROMAGNETIC
NSN Assigned:
10-DEC-84
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5945-01-196-2086 Specification Set by the OEM (see RNCC code 3)

Thread Class AAJD:

2b second mounting facility

Thread Direction AAJF:

RIGHT-Hand second mounting facility

Overall Length ABHP:

3.250in. ⁓3-1/4"

Center To Center Distance Between Mounting Facilities Parallel To Width ABKR:

2.880in. first mounting facility

Overall Height ABKW:

4.520in.

Overall Width ABMK:

3.090in.

Case Material ADTV:

plastic

Environmental Protection ADZC:

dustproof

Unthreaded Mounting Hole Diameter AEBV:

0.199in. first mounting facility

Center To Center Distance Between Mounting Facilities Parallel To Height AEBW:

0.500in. second mounting facility

Fragility Factor AFJN:

moderately rugged

End Item Identification AGAV:

compressor

Frequency In Hertz AJSS:

60.0

Winding Quantity AKDX:

1

Purpose For Which Designed AKSL:

general

Coil Quantity APCN:

1

Duty Type APNP:

continuous

Arc Quenching Method APNQ:

air

Mounting Facility Type And Quantity AXHR:

6 unthreaded hole first mounting facility

Storage Type BBRG:

general purpose warehouse

Cubic Measure CBME:

45.392 cubicin.

Thread Quantity Per Inch CMLP:

32 second mounting facility

Nominal Thread Size CQJX:

0.164in. second mounting facility ⁓11/64"

Mounting Facility Pattern CQYJ:

rectangular second mounting facility

Nonpile-up Main Contact Arrangement CRNG:

2 pole, double throw, one position momentary

Time Delay CRXH:

5.00 seconds fixed operate time and 50.00 seconds fixed operate time

Nonpile-up Auxiliary Contact Arrangement CSKP:

1 pole, double throw, one position momentary

Auxiliary Contact Maximum Voltage Rating In Volts CSQC:

480.0 ac

Operating Voltage Rating And Type At Specified Temp CSXF:

120.0 volts ac 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage CTDL:

10.0 amperes ac resistive load and 10.0 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts CWAB:

240.0 ac and 30.0 dc

Auxiliary Contact Load Current Rating At Maximum Rated Voltage CWGM:

10.0 probe ac resistive load

Energizing Element Power Rating CWJB:

8.0 watts

Thread Series Designator THSD:

unc second mounting facility

Terminal Type And Quantity TTQY:

11 screw all functions

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
7012ADT
Cage Code:
89020
RNCC:
3
RNVC:
2
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
32512
FIIG:
A03300
Concept No.:
1
App. Key:
A
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "RELAY,ELECTROMAGNETIC"

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
3.3 X 3.1 X 4.5
Paclk Weight:
2.2000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5945-01-196-2086 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.