NSN 5945-01-162-0519 NIIN 011620519 — Electromagnetic Relay

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5945-01-162-0519
5945011620519
Description:
RELAY,ELECTROMAGNETIC
NSN Assigned:
14-SEP-83
DEMIL:
 DEMIL
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5945-01-162-0519 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

2.500in. ⁓2-1/2"

Center To Center Distance Between Mounting Facilities Parallel To Length ABKQ:

1.750in. single mounting facility

Center To Center Distance Between Mounting Facilities Parallel To Width ABKR:

1.000in. single mounting facility

Overall Height ABKW:

2.125in.

Overall Width ABMK:

1.600in.

Mounting Slot Width ABTD:

0.150in. single mounting facility

Case Material ADTV:

metal

Environmental Protection ADZC:

hermetic

Fragility Factor AFJN:

moderately rugged

Frequency In Hertz AJSS:

400.0

Winding Quantity AKDX:

1

Purpose For Which Designed AKSL:

general

Coil Quantity APCN:

1

Duty Type APNP:

continuous

Arc Quenching Method APNQ:

air

Mounting Facility Type And Quantity AXHR:

4 slotted hole single mounting facility

Storage Type BBRG:

general purpose warehouse

Cubic Measure CBME:

8.500 cubicin.

Mounting Facility Pattern CQYJ:

rectangular single mounting facility

Nonpile-up Main Contact Arrangement CRNG:

2 pole, double throw, one position momentary

Criticality Code Justification CRTL:

ttqy

Time Delay CRXH:

0.05 seconds fixed release time

Operating Voltage Rating And Type At Specified Temp CSXF:

110.0 volts ac 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage CTDL:

4.0 amperes ac resistive load

Main Contact Maximum Voltage Rating In Volts CWAB:

110.0 ac

Terminal Type And Quantity TTQY:

8 wire hook all functions

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
6999ED1041
Cage Code:
27192
RNCC:
3
RNVC:
1
DAC:
C
RNAAC:
HX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
32512
FIIG:
A03300
Concept No.:
1
App. Key:
A
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "RELAY,ELECTROMAGNETIC"

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

5945-01-162-0519 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
Y
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality Y

The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restrictions or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
NRP
SOS:
X3
MMAC:
MCC:
SOS:
NRP
SOS:
MMAC:
MCC:
Source of Supply (SOS) NRP

Navicp-erp 700 robbins avenue philadelphia, pa 19111-5099

Special Material (SMIC) X3

Nuclear reactor plant (nrp) material under the technical cognizance of the navsea 08 special desinged, manufactured and/or treated for use in a nrp or controls thereof. this category includes all other nrp items which are not coded x2 or x4.

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.