NSN 5945-01-043-0168 NIIN 010430168 — Electrical Solenoid

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5945-01-043-0168
5945010430168
Description:
SOLENOID,ELECTRICAL
NSN Assigned:
19-JUN-77
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5945-01-043-0168 Specification Set by the OEM (see RNCC code 3)

Body Style AAQL:

O-Frame

Center To Center Distance Between Mounting Facilities Parallel To Length ABKQ:

1.000in.

Center To Center Distance Between Mounting Facilities Parallel To Width ABKR:

1.187in.

Body Length ADAQ:

3.430in.

Body Width ADAT:

1.560in.

Body Height ADAU:

1.560in.

Case Material ADTV:

plastic

Actuator Length AFGK:

0.750in.

Actuator Diameter AFUR:

0.788in.

Actuator Width AFUT:

0.156in.

Inclosure Type AKNA:

fully inclosed

Magnetic Coil Quantity APAF:

1

Electrical Resistance APCC:

0.65 ohms

Duty Type APNP:

continuous

Terminal Location APXH:

top edge near both ends

Electric Power Rating ARQE:

12.00 watts

Voltage Rating In Volts ASXH:

28.0 dc

Mounting Facility Type And Quantity AXHR:

4 threaded hole

Actuator Stroke Type CNXT:

pull and push

Linear Force Delivered CNXW:

80.00 ounces

Power Takeoff Connection Type CNXX:

PLAIN-Drilled

Nominal Thread Size CQJX:

0.190in. mounting facility hole ⁓13/64"

Mounting Facility Pattern CQYJ:

four position rectangular

Special Features FEAT:

solenoid to be furnished by mfr complete with spring and retaining ring and retaining ring groove in plunger

Test Data Document TEST:

14028-522394-A drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

Thread Series Designator THSD:

unf mounting facility hole

Terminal Type And Quantity TTQY:

2 solder stud

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
522394
Cage Code:
14028
RNCC:
3
RNVC:
2
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
124862
Cage Code:
14028
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
522398
Cage Code:
14028
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00310
FIIG:
A134A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A
BODY STYLE O-FRAME style nsn 5945-01-043-0168

Definition Definition of approved item name (AIN): "SOLENOID,ELECTRICAL"

An item consisting of one or more coils surrounding an iron core. The coil(s) and the core are moveable in relation to each other. The axial or rotary movement is a result of the magnetic flux of the coil. It is designed to convert electrical energy into mechanical energy. It does not include switch contacts. See also relay, electromagnetic, and electromagnetic actuator.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
1.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5945-01-043-0168 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.