NSN 5945-00-825-4510 NIIN 008254510 — Electromagnetic Relay

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5945-00-825-4510
5945008254510
Description:
RELAY,ELECTROMAGNETIC
NSN Assigned:
01-JAN-62
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5945-00-825-4510 Specification Set by the OEM (see RNCC code 3)

Thread Class AAJD:

2a single mounting facility

Overall Length ABHP:

3.150in. ⁓3-5/32"

Center To Center Distance Between Mounting Facilities Parallel To Length ABKQ:

1.375in. single mounting facility

Center To Center Distance Between Mounting Facilities Parallel To Width ABKR:

1.375in. single mounting facility

Overall Height ABKW:

1.500in.

Overall Width ABMK:

1.500in.

Environmental Protection ADZC:

hermetic

Winding Quantity AKDX:

1

Coil Quantity APCN:

1

Winding Dc Resistance Rating APNA:

1.6 kilohms single winding

Duty Type APNP:

continuous

Mounting Facility Type And Quantity AXHR:

2 threaded stud single mounting facility

Pile-up Main Contact Form Arrangement AYSC:

1c

Nominal Thread Size CQJX:

0.138in. single mounting facility ⁓9/64"

Mounting Facility Pattern CQYJ:

diagonal single mounting facility

Nominal Operating Current Rating And Type CRPQ:

0.8 milliamperes dc single winding

Operating Voltage Rating And Type At Specified Temp CSXF:

12.5 volts dc 25 deg celsius single winding

Main Contact Load Current Rating At Maximum Rated Voltage CTDL:

1.5 amperes ac resistive load and 1.5 amperes dc resistive load

Main Contact Maximum Voltage Rating In Volts CWAB:

120.0 ac and 28.0 dc

Thread Series Designator THSD:

unc single mounting facility

Terminal Type And Quantity TTQY:

5 pin all functions

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
5RJ16000GS1L
Cage Code:
03848
RNCC:
3
RNVC:
9
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
32512
FIIG:
A03300
Concept No.:
1
App. Key:
A
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "RELAY,ELECTROMAGNETIC"

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5945-00-825-4510 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.