NSN 5945-00-532-0042 NIIN 005320042 — Electrical Solenoid

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5945-00-532-0042
5945005320042
Description:
SOLENOID,ELECTRICAL
NSN Assigned:
01-JAN-63
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5945-00-532-0042 Specification Set by the OEM (see RNCC code 3)

Thread Class AAJD:

2a mounting facility stud

Thread Direction AAJF:

RIGHT-Hand mounting facility stud

Body Style AAQL:

base end actuator

Thread Length AASA:

0.533in. mounting facility stud and 0.563in. mounting facility stud ⁓37/64"

Bolt Circle Diameter ABKG:

0.875in.

Body Diameter ABPM:

1.302in. and 1.343in.

Body Height ADAU:

0.797in.

Actuator Length AFGK:

0.479in. and 0.499in.

Actuator Diameter AFUR:

0.1865in. and 0.1885in.

Inclosure Type AKNA:

fully inclosed

Magnetic Coil Quantity APAF:

1

Electrical Resistance APCC:

12.21 ohms

Duty Type APNP:

continuous

Terminal Location APXH:

circumference

Electric Power Rating ARQE:

9.0 watts

Voltage Rating In Volts ASXH:

10.4 dc

Mounting Facility Type And Quantity AXHR:

2 threaded stud

Torque Rating And Type BKPH:

0.25 INCH-Pounds starting

Thread Quantity Per Inch CMLP:

40 mounting facility stud

Actuator Stroke Type CNXT:

rotary

Power Takeoff Connection Type CNXX:

plain

Nominal Thread Size CQJX:

0.125in. mounting facility stud ⁓1/8"

Mounting Facility Pattern CQYJ:

two position IN-Line

Rotation Direction And Energizing Stroke In Angular Deg CSQY:

35.0 clockwise

Thread Series Designator THSD:

unc mounting facility stud

Terminal Type And Quantity TTQY:

2 wire lead

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
BD3ER35-29X9
Cage Code:
81840
RNCC:
5
RNVC:
1
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
H3250-029
Cage Code:
81840
RNCC:
3
RNVC:
2
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00310
FIIG:
A134A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A
BODY STYLE BASE END ACTUATOR style nsn 5945-00-532-0042

Definition Definition of approved item name (AIN): "SOLENOID,ELECTRICAL"

An item consisting of one or more coils surrounding an iron core. The coil(s) and the core are moveable in relation to each other. The axial or rotary movement is a result of the magnetic flux of the coil. It is designed to convert electrical energy into mechanical energy. It does not include switch contacts. See also relay, electromagnetic, and electromagnetic actuator.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5945-00-532-0042 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.