NSN 5940-01-309-6319 NIIN 013096319 — Terminal Board

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5940-01-309-6319
5940013096319
Description:
TERMINAL BOARD
NSN Assigned:
20-OCT-89
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5940-01-309-6319 Specification Set by the OEM (see RNCC code 3)

Mounting Hole Diameter AAMA:

0.156in.

Body Style AAQL:

strip type

Board Construction ABCX:

solid construction

Center To Center Distance Between Mounting Facilities Parallel To Length ABDU:

3.015in.

Distance From Bottom Edge Of Terminal Board To Center Of Mounting Hole ABDW:

0.150in.

Distance From Left Edge Of Terminal Board To Center Of First Mounting Facility ABDX:

0.130in.

Board Overall Length ABGN:

3.300in.

Board Overall Width ABGP:

0.300in.

Board Thickness ABGT:

0.062in.

Mounting Facility Type And Quantity AXHR:

2 unthreaded hole

Feedthru Connection End Type CQCW:

439 15th material response both ends

Feedthru Terminal Quantity CRZR:

8 single combination

Terminal Pattern Arrangement CWLG:

random

Terminal Design CWLN:

feedthru

Special Features FEAT:

special requirements for nuclear propulsion plant equipment contained in individual repair parts ordering data instrumentation irpod si no. C13LADB02A, plisn no. 0077

Special Markings MARK:

1 thru 8, P17

Material MATT:

glass board

Reference Number Differentiating Characteristics ZZZY:

as differentiated by special features

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
KWF354-1
Cage Code:
02750
RNCC:
3
RNVC:
1
DAC:
A
RNAAC:
CX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00404
FIIG:
A011B0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A
BODY STYLE STRIP TYPE style nsn 5940-01-309-6319

Definition Definition of approved item name (AIN): "TERMINAL BOARD"

An item consisting of insulating material, which is specifically designed to have fastened thereon, or on which are fastened terminal(s), such as screws, solder lugs, solder studs, solderless connectors, clips, and the like. It is usually used for junctions or terminations of wire or cable assemblies. It does not include items as defined above with parts, such as resistors and capacitors mounted thereon. Do not use if a more specific name exists, such as fuseholder; holder, resistor; fanning strip; contact assembly, electrical; jack assembly, tip; chamber, cable terminal; panel (2) (as modified); connector (as modified). Excludes terminal, stud; terminal, feedthru, insulated; post, binding, electrical; and chassis, electrical-electronic equipment. For items having printed electrical conductor paths, see printed wiring board.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.1000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5940-01-309-6319 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.