NSN 5940-00-224-6023 NIIN 002246023 — Terminal Box

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5940-00-224-6023
5940002246023
Description:
TERMINAL BOX
NSN Assigned:
01-JAN-63
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5940-00-224-6023 Specification Set by the OEM (see RNCC code 3)

Overall Depth ABFY:

0.968in.

Center To Center Distance Between Mounting Facilities Parallel To Width ABKR:

1.562in.

Overall Height ABKW:

3.125in.

Overall Width ABMK:

1.875in.

Unthreaded Mounting Hole Diameter AEBV:

0.154in.

Center To Center Distance Between Mounting Facilities Parallel To Height AEBW:

1.250in.

Standard Mounting Pattern Designator AESL:

3 POINT-Triangular

Cable Entrance Diameter AFQJ:

0.281in. and 0.250in.

Cable Opening Length AGTX:

0.562in.

Mounting Method AXGY:

unthreaded hole

Features Provided CBBL:

cover

Terminal Type And Quantity CCFF:

4 double screw

Entrance Type And Quantity CPLF:

2 prepunched hole

Material MATT:

copper alloy and steel and plastic phenolic

Surface Treatment SFTT:

nickel

Style Designator STYL:

rectangular, surface mounting

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
114E3048-1
Cage Code:
77272
RNCC:
3
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
J193AR
Cage Code:
80058
RNCC:
3
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
6014
Cage Code:
78711
RNCC:
5
RNVC:
2
DAC:
1
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
114E3048-1
Cage Code:
81205
RNCC:
5
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00452
FIIG:
A17600
Concept No.:
App. Key:
F
Cond. Code:
1
Status:
A
STYLE DESIGNATOR RECTANGULAR, SURFACE MOUNTING style nsn 5940-00-224-6023
STANDARD MOUNTING PATTERN DESIGNATOR 3 POINT-TRIANGULAR style nsn 5940-00-224-6023

Definition Definition of approved item name (AIN): "TERMINAL BOX"

An enclosure which includes, mounts and protects one or more terminals and/or terminal boards. It is designed for and may include a cover and such accessories as mounting hardware, brackets, locks, and conduit fittings. For boxes which include combinations of different electrical devices such as terminals and/or terminal boards, fuseholders, switches, jacks, circuit breakers, connectors and the like, see distribution box. For boxes which are designed to mount, but which do not include terminals and/or terminal boards, see junction box. Excludes terminal board assembly. See also chamber, cable terminal; and interconnecting cabinet.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
LVL_A:
E
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5940-00-224-6023 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.