NSN 5935-01-624-4974 NIIN 016244974 — Electrical Connector Backshell

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5935-01-624-4974
5935016244974
Description:
BACKSHELL,ELECTRICAL CONNECTOR
NSN Assigned:
06-JAN-14
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5935-01-624-4974 Specification Set by the OEM (see RNCC code 3)

Thread Class AAJD:

2a

Thread Direction AAJF:

RIGHT-Hand

Overall Length ABHP:

38.0 mm

Center To Center Distance Between Mounting Facilities Parallel To Length ABKQ:

18.2 mm

Center To Center Distance Between Mounting Facilities Parallel To Width ABKR:

18.2 mm

Overall Width ABMK:

25.4 mm

Flange Length AFQN:

25.4 mm

End Item Identification AGAV:

stryker

Thread Quantity Per Inch CMLP:

24

Nominal Thread Size CQJX:

0.625in. ⁓5/8"

Thread Tolerance Class CTTC:

2a internal

Part Name Assigned By Controlling Agency CXCY:

n panel jack to jack adapter

Special Features FEAT:

contact pin material phosphate bronze with gold finish; body material brass with nexcote finish

Material MATT:

copper alloy

Thread Series Designator THSD:

unef

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
172278
Cage Code:
SJC41
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
67169
FIIG:
A10100
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "BACKSHELL,ELECTRICAL CONNECTOR"

An item specifically designed to be placed around that portion of a connector, receptable, electrical or connector, plug, electrical which contains the facilities for attaching wires or cables. it may be designed to provide the necessary accomodations between an electrical cable clamping device and an electrical connector shell, or it may include the clamping device. it may be used for shielding against electrical interference, mechanical injury, or physical damage due to environmental conditions.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
1.6 X 1.1 X 0.9
Paclk Weight:
0.3000lbs
Item Weight:
0.2000lbs
Item Dim:
001500100008
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
2
LVL_B:
A
LVL_C:
U
LVL A Code (LVL_A) 2

Packing shall be accomplished using cleated plywood boxes, overseas type, conforming to astm-d6251, type iii, class 2, or nailed wood boxes conforming to astm-d6880, class 2, heavy duty.

LVL B Code (LVL_B) A

Packing shall be accomplished using fiberboard boxes, weather resistant class, fabricated in accordance with astm-d5118, or triplewall fiberboard boxes conforming to astm-d5168, class weather resistant.

LVL C Code (LVL_C) U

Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) postal regulations, (b) department of transportation regulations, (c) civil air regulations, (d) uniform freight classification rules, (e) national motor freight classification rules, (f) american truckers' association rules, (g) other applicable carriers' rules, (h) military air regulations for dangerous materials. consolidation of shipments. all exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. dangerous goods shall be prepared for shipment according to applicable department of transportation (dot) regulations and international regulations in effect at time of shipment. shipment by parcel post must comply with postal regulations.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5935-01-624-4974 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
A
ESD:
A
ADPE:
0
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

Electrostatic Discharge (ESD) A

No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.