Serving our customers with quality and safety first.
2a and 2a and 2a
RIGHT-Hand and RIGHT-Hand and RIGHT-Hand
straight shape, external coupling
1.230in. ⁓1-15/64"
vibration resistant and shock resistant and thermal shock resistant and moisture resistant and pressure proof
coupling facility and mounting bushing
2
sma 1st mating endnonstd 2nd mating end
nonremovable all mating ends single contact grouping
335.0 all mating ends single contact grouping
18.0 gigahertz all mating ends single contact grouping
solid
externally threaded shell
50.0 all mating ends single contact grouping
0.688in. ⁓45/64"
-65.0 deg celsius and 165.0 deg celsius
36 and 28 and 28
0.250in. and 0.438in. and 0.500in. ⁓29/64"
copper alloy all mating ends single contact grouping
gold all mating ends single contact grouping and copper all mating ends single contact grouping
plastic polytetrafluoroethylene all mating ends
MIL-G-45204, type ii, class 2 mil spec 1st treatment response all mating ends single contact grouping and MIL-C-14550, class 4 mil spec 2nd treatment response all mating ends single contact grouping
QQ-C-530 fed spec single material response all mating ends single contact grouping
steel corrosion resisting
passivate
QQ-P-35, type 1 fed spec single treatment response
AMS-5640, type 303, condition a assn std single material response
MIL-P-19468 mil spec single material response all mating ends or L-P-403, type 1 fed spec single material response all mating ends
1 1st mating end single contact GROUPING1 2nd mating end single contact grouping
round w/flat
coaxial socket all mating ends single contact grouping
contact surfaces gold
0.010 gold grains, troy
gold
uns and unef and unef
An adapter with electrical contacts which provides facilities for joining two or more electrical connectors, whose design or function will not normally warrant their junction. it is not designed for permanent attachment to a cable, cord, coaxial line, or wire. the physical shape of an electrical connector should not be the determining factor of its name. tee, angle, straight, and y-shaped adapters are all adapter, connector. excludes adapter, connector to lampbase; adapter, lampholder to connector; adapter (1), cable clamp to connector; and adapter, lampholder. for items designed as a mechanical connection between an electrical conduit and an electrical connector, see adapter (1), electrical conduit.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.
No special marking.
OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.
SPI No.: Special packaging instructions number.
LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.
SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item contains gold.
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.
Defense logistics agency, enterprise business systems
Electronic components (engineering support at the 88th ose/oss)
SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.
SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.
MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.
MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category
IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.