Serving our customers with quality and safety first.
straight shape
1.800in. ⁓1-13/16"
3.095in. and 3.125in.
1.985in. and 2.015in.
corrosion resistant and humidity resistant and salt water resistant and shock resistant and thermal shock resistant and vibration resistant
0.118in.
2.783in.
1.437in.
0.758in. and 0.764in.
2
"106, A106" 2nd mating end
removable 1st mating end 2nd contact groupingremovable 2nd mating end single contact grouping
3 polarization posts
solid
friction
-65.0 deg celsius and 125.0 deg celsius
back 1st mating end 2nd contact groupingback 2nd mating end single contact grouping
copper alloy 1st mating end 2nd contact groupingcopper alloy 2nd mating end single contact grouping
gold 1st mating end 2nd contact groupinggold 2nd mating end single contact grouping
plastic diallyl phthalate glass filled all mating ends or plastic epoxy all mating ends or plastic phenolic all mating ends
MIL-G-45204, type 2, grade c, class 1 mil spec single treatment response 1st mating end 2nd contact GROUPINGMIL-G-45204, type 2, grade c, class 1 mil spec single treatment response 2nd mating end single contact grouping
crimp 1st mating end 2nd contact groupingcrimp 2nd mating end single contact grouping
hexagon shape male post RIGHT-Hand at 1 oclock hexagon shape male post center at 5 oclock hexagon shape male post LEFT-Hand at 7 oclock
aluminum alloy
cadmium and chromate
QQ-P-416, type 2 fed spec all treatment responses
QQ-A-591 fed spec single material response or QQ-A-367 fed spec single material response or QQ-A-250 fed spec single material response
MIL-M-14, type GDI-30F or SDG-F mil spec 1st material response all mating ends or allied chemical 1288 bx mfr ref 2nd material response all mating ends or MIL-M-14 mil spec 3rd material response all mating ends
29 1st mating end 2nd contact GROUPING106 2nd mating end single contact grouping
round pin 1st mating end 2nd contact groupinground pin 2nd mating end single contact grouping
contact surfaces gold
0.135 gold grains, troy
gold
An electrical fitting with electrical contacts constructed to be affixed to the end of a cable, conduit, coaxial line, cord, wire (includes printed/etched), printed wiring board, or the like for convenience in joining with another electrical connector(s) or printed wiring board. It is designed to be mounted on a bulkhead, chassis, panel, wall, printed wiring board, or the like. Excludes lampholder; jack, telephone; jack, tip; insert electrical connector; insert module, electrical connector; connector body (as modified) and socket, plug-in electronic components. See also wiring harness (as modified) and cable assembly (as modified). For items with termination wires of more than four inches in length, see lead assembly, electrical. For items without inserts, see shell, electrical connector.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.
No special marking.
OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.
SPI No.: Special packaging instructions number.
LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.
SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item contains gold.
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.