Serving our customers with quality and safety first.
straight shape w/screw locks
175.2 mm and 175.8 mm
28.2 mm
7.9 mm
shock resistant and vibration resistant and corrosion resistant and humidity resistant and fungus resistant
1
2 rows of contacts NON-Inserted board single mating end
nonremovable single mating end single contact grouping
5.0 single mating end single contact grouping
guide pin/socket
friction
-65.0 deg celsius and 125.0 deg celsius
back single mating end single contact grouping
copper alloy single mating end single contact grouping
gold single mating end single contact grouping and nickel single mating end single contact grouping or gold single mating end single contact grouping and copper single mating end single contact grouping
plastic diallyl phthalate glass filled single mating end or plastic polyester glass filled single mating end
MIL-G-45204, ty 2, cl 1, grade c mil spec 1st treatment response single mating end single contact grouping and QQ-N-290, cl 2 fed spec 2nd treatment response single mating end single contact grouping or MIL-G-45204, ty 2, cl 1, grade c mil spec 3rd treatment response single mating end single contact grouping and MIL-C-14550, cl 4 mil spec 4th treatment response single mating end single contact grouping
pin single mating end single contact grouping
QQ-C-530 fed spec single material response single mating end single contact grouping or QQ-533 fed spec single material response single mating end single contact grouping or QQ-750 fed spec single material response single mating end single contact grouping
key shape pin LEFT-Hand at 3 oclock and key shape pin RIGHT-Hand at 3 oclock
MIL-M-14, ty SDG-F or ty GDI-30F mil spec 1st material response single mating end or MIL-M-24519, ty GPT-30F or GST-40F mil spec 2nd material response single mating end
120 single mating end single contact grouping
round socket single mating end single contact grouping
contact surfaces gold
0.120 gold grains, troy
gold
81349-DOD-C-55302 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
81349-DOD-C-55302/163 government specification
An electrical fitting with electrical contacts, constructed to be affixed to the end of a cable, conduit, coaxial line, cord or wiring for convenience in joining with other electrical connector(s) or printed wiring board and is not designed to be mounted on a bulkhead, chasses, panel, printed wiring board, or the like. Excludes jack, telephone; jack, tip; plug, telephone; plug tip; insert, electrical connector; connector body (as modified); and socket, plug-in, electronic components. see also lead assembly, electrical; wiring harness (as modified); and cable assembly (as modified). for items without inserts, see shell, electrical connector.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.
No special marking.
OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.
SPI No.: Special packaging instructions number.
LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.
SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item contains gold.
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.
Defense logistics agency, enterprise business systems
Electronic components (engineering support at the 88th ose/oss)
SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.
SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.
MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.
MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category
IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.