NSN 5935-01-279-5175 NIIN 012795175 — Receptacle Electrical Connector

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5935-01-279-5175
5935012795175
Description:
CONNECTOR,RECEPTACLE,ELECTRICAL
NSN Assigned:
20-MAY-88
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5935-01-279-5175 Specification Set by the OEM (see RNCC code 3)

Body Style AAQL:

straight type

Overall Length ABHP:

7.500in. ⁓7-1/2"

Overall Width ABMK:

0.522in.

Environmental Protection ADZC:

humidity resistant and salt water resistant and thermal shock resistant and vibration resistant and cold resistant and heat resistant

Unthreaded Mounting Hole Diameter AEBV:

0.068in.

Distance Between Mounting Facility Centers AEJN:

7.300in.

Mating End Quantity AFQW:

1

Contact Position Arrangement Style AFQX:

2 rows of contacts NON-Inserted board single mating end

Contact Removability AFQZ:

nonremovable single mating end single contact grouping

Polarization Method AFRN:

guide pin/socket

Shell Type AFRT:

solid

Connector Locking Method AFRV:

friction

End Item Identification AGAV:

5865-01-262-7031 communication processor

Terminal Location CQTM:

side single mating end single contact grouping

Contact Material CQTZ:

copper alloy single mating end single contact grouping

Contact Surface Treatment CQYH:

gold single mating end single contact grouping and nickel single mating end single contact grouping

Insert Material CQZG:

plastic polyamide single mating end

Contact Surface Treatment Document And Classification CRBJ:

MIL-G-45204, ty 2, grade c, class 1 mil spec 1st treatment response single mating end single contact grouping and QQ-N-290, class 2 fed spec 2nd treatment response single mating end single contact grouping

Terminal Type CSCF:

pin single mating end single contact grouping

Contact Material Document And Classification CSGF:

QQ-B-613 fed spec single material response single mating end single contact grouping

Guide Design And Location CSLR:

d shape pin LEFT-Hand at 5 oclock and d shape pin RIGHT-Hand at 5 oclock

Shell Material CSPT:

aluminum alloy 6063

Shell Surface Treatment CSWM:

chromate

Shell Surface Treatment Document And Classification CTBC:

MIL-C-5541, cl 1 mil spec single treatment response

Shell Material Document And Classification CTHH:

QQ-A-200 fed spec single material response

Insert Material Document And Classification CTKL:

MIL-M-20693, ty 1 mil spec single material response single mating end

Included Contact Quantity CXCG:

140 single mating end single contact grouping

Included Contact Type CXCL:

flat pin single mating end single contact grouping

Precious Material And Location PMLC:

contact surfaces gold

Precious Material And Weight PMWT:

0.140 gold grains, troy

Precious Material PRMT:

gold

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
M1001-08260
Cage Code:
77820
RNCC:
C
RNVC:
1
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
9X
Part Number:
F-1188-28
Cage Code:
23880
RNCC:
5
RNVC:
2
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
C5107495-28
Cage Code:
57958
RNCC:
3
RNVC:
9
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
M1001-08260
Cage Code:
31413
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
15093
FIIG:
A039B0
Concept No.:
App. Key:
K
Cond. Code:
1
Status:
A
BODY STYLE STRAIGHT TYPE style nsn 5935-01-279-5175
BODY STYLE STRAIGHT TYPE style nsn 5935-01-279-5175
BODY STYLE STRAIGHT TYPE style nsn 5935-01-279-5175
BODY STYLE STRAIGHT TYPE style nsn 5935-01-279-5175

Definition Definition of approved item name (AIN): "CONNECTOR,RECEPTACLE,ELECTRICAL"

An electrical fitting with electrical contacts constructed to be affixed to the end of a cable, conduit, coaxial line, cord, wire (includes printed/etched), printed wiring board, or the like for convenience in joining with another electrical connector(s) or printed wiring board. It is designed to be mounted on a bulkhead, chassis, panel, wall, printed wiring board, or the like. Excludes lampholder; jack, telephone; jack, tip; insert electrical connector; insert module, electrical connector; connector body (as modified) and socket, plug-in electronic components. See also wiring harness (as modified) and cable assembly (as modified). For items with termination wires of more than four inches in length, see lead assembly, electrical. For items without inserts, see shell, electrical connector.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5935-01-279-5175 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
G
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) G

Item contains gold.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.