Serving our customers with quality and safety first.
2a and 2a and 2b
RIGHT-Hand and RIGHT-Hand and RIGHT-Hand
straight shape, external coupling
33.66 mm
28.6 mm
28.6 mm
20.62 mm and 23.00 mm
20.62 mm and 23.00 mm
20.9 mm
back shell and coupling facility and hub
12
13-35 single mating end
keyway or multiple keyway and key, multiple key groove
0.0 and 124.0 and 152.0 and 219.0 and 265.0
solid
externally threaded shell
10 and 32 and 18
18.0 mm and 0.875in.
1.00 and 1.00
plastic epoxy single mating end and glass single mating end
aluminum alloy or zinc
cadmium and chromate or nickel
QQ-P-416 ty ii, cl 3 fed spec single treatment response
6g external and 6h internal
81349-MIL-C-38999 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .
iso m and special acme
81349-MIL-C-38999/20 government specification
The main or principal part of a connector, receptacle, electrical which includes insert(s) designed to accommodate but does not include removable contacts. It may have a hood or shell, a jackscrew and jacksocket, or other means for polarizing and aligning. It is designed to be mounted on a bulkhead, chassis, panel, wall, or the like. Excludes connector body, modular receptacle, electrical. For items without inserts, see shell, electrical connector.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.
No special marking.
OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.
SPI No.: Special packaging instructions number.
LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.
SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item does not contain precious metal.
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.