Serving our customers with quality and safety first.
2a
RIGHT-Hand
straight shape
1.509in. ⁓1-33/64"
2.429in.
1.421in.
moisture resistant and shock resistant and thermal shock resistant and vibration resistant
0.120in.
2.104in.
0.906in.
0.508in.
mounting stud
2
removable all mating ends all contact groupings
7.5 all mating ends all contact groupings
mating end
solid
40
0.112in. ⁓1/8"
back all mating ends all contact groupings
copper alloy all mating ends all contact groupings
nickel all mating ends all contact groupings and gold all mating ends all contact groupings
plastic diallyl phthalate all mating ends
QQ-N-290 fed spec 1st treatment response all mating ends all contact groupings and MIL-G-45204 ty 2, cl 2 mil spec 2nd treatment response all mating ends all contact groupings
crimp all mating ends all contact groupings
aluminum alloy
zinc
QQ-Z-325 fed spec single treatment response
QQ-A-591 fed spec single material response
MIL-M-14 ty SDG-F mil spec single material response all mating ends
8 1st mating end single contact grouping
contact surfaces gold
0.031 gold grains, troy
gold
unc
An electrical fitting with electrical contacts constructed to be affixed to the end of a cable, conduit, coaxial line, cord, wire (includes printed/etched), printed wiring board, or the like for convenience in joining with another electrical connector(s) or printed wiring board. It is designed to be mounted on a bulkhead, chassis, panel, wall, printed wiring board, or the like. Excludes lampholder; jack, telephone; jack, tip; insert electrical connector; insert module, electrical connector; connector body (as modified) and socket, plug-in electronic components. See also wiring harness (as modified) and cable assembly (as modified). For items with termination wires of more than four inches in length, see lead assembly, electrical. For items without inserts, see shell, electrical connector.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.
No special marking.
OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.
SPI No.: Special packaging instructions number.
LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.
SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item contains gold.
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.
Defense logistics agency, enterprise business systems
Electronic components (engineering support at the 88th ose/oss)
SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.
SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.
MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.
MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category
IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.