Serving our customers with quality and safety first.
2a and 2a
RIGHT-Hand and RIGHT-Hand
straight shape threaded
1.531in. ⁓1-17/32"
1.740in. and 1.760in. ⁓1-49/64"
1.146in. and 1.166in.
0.094in. and 0.250in.
coupling facility and mounting bushing
1
18-9 single mating end
nonremovable single mating end all contact groupings
41.0 single mating end 2nd contact grouping
200.0 single mating end all contact groupings
250.0 single mating end all contact groupings
key, multiple key groove
250.0
solid
externally threaded shell
10
1.125in. and 1.250in. ⁓1-1/4"
0.10
back single mating end all contact groupings
steel single mating end all contact groupings
silver single mating end all contact groupings and copper alloy single mating end all contact groupings
rubber synthetic single mating end or rubber synthetic single mating end or rubber synthetic single mating end or rubber synthetic single mating end
QQ-S-365, type 2 fed spec 1st treatment response single mating end all contact groupings
solder well single mating end all contact groupings
aluminum alloy or aluminum alloy or aluminum alloy or aluminum alloy or aluminum alloy
anodize
MIL-F-14072, finish E516 mil spec single treatment response
QQ-A-367, comp 3 fed spec 1st material response or QQ-A-367, comp 11 fed spec 2nd material response or QQ-A-270 fed spec 3rd material response or QQ-A-325 fed spec 4th material response or WW-T-789 fed spec 5th material response
MIL-R-3065, class SC717A mil spec 1st material response single mating end or MIL-R-3065, class SC717B mil spec 2nd material response single mating end or MIL-R-3065, class SC717E mil spec 3rd material response single mating end or MIL-R-3065, class SC717F mil spec 4th material response single mating end
5 single mating end 1st contact grouping
round keyed
round socket single mating end all contact groupings
rubber durometer hardness no. is 65 to 85
contact surface silver
silver
double stub and unef
An electrical fitting with electrical contacts constructed to be affixed to the end of a cable, conduit, coaxial line, cord, wire (includes printed/etched), printed wiring board, or the like for convenience in joining with another electrical connector(s) or printed wiring board. It is designed to be mounted on a bulkhead, chassis, panel, wall, printed wiring board, or the like. Excludes lampholder; jack, telephone; jack, tip; insert electrical connector; insert module, electrical connector; connector body (as modified) and socket, plug-in electronic components. See also wiring harness (as modified) and cable assembly (as modified). For items with termination wires of more than four inches in length, see lead assembly, electrical. For items without inserts, see shell, electrical connector.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item contains silver.
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.
Defense supply center columbus, columbus, oh 43218
SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.
SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.
MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.
MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category
IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.