NSN 5935-00-259-9849 NIIN 002599849 — Receptacle Electrical Connector

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5935-00-259-9849
5935002599849
Description:
CONNECTOR,RECEPTACLE,ELECTRICAL
NSN Assigned:
01-JAN-61
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5935-00-259-9849 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

0.848in. ⁓55/64"

Overall Diameter ADAV:

0.375in. ⁓3/8"

Environmental Protection ADZC:

oil resistant

Threaded Device Type AFQR:

mounting hole

Mating End Quantity AFQW:

1

Connector Locking Method AFRV:

bayonet latch

Thread Quantity Per Inch CMLP:

32

Nominal Thread Size CQJX:

0.375in. ⁓3/8"

Insert Material CQZG:

plastic all mating ends

Shell Material CSPT:

aluminum alloy

Included Contact Quantity CXCG:

1 single mating end single contact grouping

Special Features FEAT:

single through hole mtg

Thread Series Designator THSD:

unef

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
MILC3608
Cage Code:
81349
RNCC:
4
RNVC:
1
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
87125
Cage Code:
30684
RNCC:
3
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
568111
Cage Code:
57733
RNCC:
3
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
UG912AU
Cage Code:
80058
RNCC:
3
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
87125
Cage Code:
74868
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
4610015205
Cage Code:
D8385
RNCC:
5
RNVC:
2
DAC:
6
RNAAC:
ZG
Status:
A
MSDS:
SADC:
Part Number:
REB49053
Cage Code:
80064
RNCC:
5
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
MS35183-912
Cage Code:
96096
RNCC:
5
RNVC:
9
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
15093
FIIG:
A039B0
Concept No.:
App. Key:
K
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "CONNECTOR,RECEPTACLE,ELECTRICAL"

An electrical fitting with electrical contacts constructed to be affixed to the end of a cable, conduit, coaxial line, cord, wire (includes printed/etched), printed wiring board, or the like for convenience in joining with another electrical connector(s) or printed wiring board. It is designed to be mounted on a bulkhead, chassis, panel, wall, printed wiring board, or the like. Excludes lampholder; jack, telephone; jack, tip; insert electrical connector; insert module, electrical connector; connector body (as modified) and socket, plug-in electronic components. See also wiring harness (as modified) and cable assembly (as modified). For items with termination wires of more than four inches in length, see lead assembly, electrical. For items without inserts, see shell, electrical connector.

5935-00-259-9849 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.