NSN 5930-01-339-0319 NIIN 013390319 — Rotary Switch

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5930-01-339-0319
5930013390319
Description:
SWITCH,ROTARY
NSN Assigned:
15-MAY-91
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Air Force

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5930-01-339-0319 Specification Set by the OEM (see RNCC code 3)

Thread Class AAJD:

2a single mounting facility

Thread Length AASA:

0.292in. single mounting facility and 0.332in. single mounting facility ⁓11/32"

Hazardous Locations/environmental Protection ABFE:

explosion proof

Overall Length ABHP:

1.636in. ⁓1-41/64"

First Flat Length ABNB:

0.230in. single actuator and 0.270in. single actuator

Flat Height ABNC:

0.084in. single actuator and 0.104in. single actuator

Shaft Diameter ABWV:

0.123in. single actuator and 0.126in. single actuator

Shaft Length ABXF:

0.355in. single actuator and 0.395in. single actuator

Overall Diameter ADAV:

0.730in. and 0.770in. ⁓25/32"

Individual Section Quantity AFBH:

2

Operating Temp Range AFGA:

-65.0/+85.0 deg celsius

Switch Contact Basic Design AJZE:

NONPILE-Up symmetrical

Pole Quantity AKPX:

1 each section rear

Throw Quantity AKPY:

12 each section rear

Mounting Method AXGY:

threaded bushing w/panel seal single mounting facility

Features Provided CBBL:

legend plate

Nominal Thread Size CQJX:

0.250in. single mounting facility ⁓1/4"

Contact Voltage Rating In Volts CQMK:

28.0 dc at sea level

Switch Actuator Indexing Position Quantity CRJH:

12 single actuator

Shaft Type CRSJ:

round, flatted single actuator

Terminal Type CSCF:

tab, solder lug

Contact Switching Action CSHW:

breaks before makes each section rear

Switch Actuator Positioning Increment CSLC:

30.0 degrees single actuator

Detent Rotational Torque Range CSMW:

+5.000/+20.000 INCH-Ounces single actuator

Switch Actuator Stop Device Type CTDN:

fixed stop single actuator

Contact Load Current Rating CTHF:

75.0 milliamperes resistive load ac at sea level

Style Designator STYL:

tap, circular, bushing mount

Test Data Document TEST:

81349-MIL-S-3786 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Thread Series Designator THSD:

unef single mounting facility

Specification/standard Data ZZZK:

81349-MIL-S-3786/39 government specification

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
M3786/39-4MB
Cage Code:
81349
RNCC:
2
RNVC:
2
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
MIL-DTL-3786/39
Cage Code:
81349
RNCC:
4
RNVC:
1
DAC:
E
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
MIL-S-3786/39
Cage Code:
81349
RNCC:
5
RNVC:
9
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
02134
FIIG:
A052B0
Concept No.:
1
App. Key:
A
Cond. Code:
1
Status:
A
STYLE DESIGNATOR TAP, CIRCULAR, BUSHING MOUNT style nsn 5930-01-339-0319
STYLE DESIGNATOR TAP, CIRCULAR, BUSHING MOUNT style nsn 5930-01-339-0319

Definition Definition of approved item name (AIN): "SWITCH,ROTARY"

A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see switch, sensitive. Excludes relay, rotary; switch, stepping; and switch, telephone (as modified).

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.1000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5930-01-339-0319 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
SMS
SOS:
MMAC:
EH
MCC:
Source of Supply (SOS) SMS

Defense logistics agency, enterprise business systems

Material Management (MMAC) EH

Electronic components (engineering support at the 88th ose/oss)

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.