NSN 5930-01-316-1751 NIIN 013161751 — Rotary Switch

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5930-01-316-1751
5930013161751
Description:
SWITCH,ROTARY
NSN Assigned:
05-MAR-90
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5930-01-316-1751 Specification Set by the OEM (see RNCC code 3)

Thread Class AAJD:

2b 1st mounting facility

Hazardous Locations/environmental Protection ABFE:

shock resistant

Overall Length ABHP:

8.063in. ⁓8-5/64"

Overall Height ABKW:

3.688in.

Overall Width ABMK:

3.812in.

Unthreaded Mounting Hole Diameter AEBV:

0.312in. 2nd mounting facility

Distance Between Mounting Facility Centers AEJN:

3.812in. 2nd mounting facility

Individual Section Quantity AFBH:

12

Switch Contact Basic Design AJZE:

NONPILE-Up symmetrical

Pole Quantity AKPX:

1 each section periphery

Throw Quantity AKPY:

1 each section periphery

Mounting Facility Circle Radius ALAQ:

1.609in. 1st mounting facility

Mounting Method AXGY:

bracket 2nd mounting facility and unthreaded hole 2nd mounting facility

Features Provided CBBL:

actuator knob

Thread Quantity Per Inch CMLP:

20 1st mounting facility

Nominal Thread Size CQJX:

0.250in. 1st mounting facility ⁓1/64"

Contact Voltage Rating In Volts CQMK:

500.0 ac at sea level

Mounting Facility Pattern CQYJ:

two position IN-Line 2nd mounting facility

Switch Actuator Indexing Position Quantity CRJH:

2 single actuator

Criticality Code Justification CRTL:

feat

Terminal Type CSCF:

tab w/screw

Contact Switching Action CSHW:

breaks before makes each section periphery

Switch Actuator Positioning Increment CSLC:

180.0 degrees single actuator

Contact Load Current Rating CTHF:

30.0 amperes resistive load ac at sea level

Special Features FEAT:

item must comply with requirements of defense electronics supply center production standard no. L04176; for navy nuclear propulsion plant products only

Style Designator STYL:

tap, circuit selector

Thread Series Designator THSD:

unc 1st mounting facility

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
133271-3
Cage Code:
94271
RNCC:
3
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
123112AA-2
Cage Code:
82121
RNCC:
5
RNVC:
2
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
02134
FIIG:
A052B0
Concept No.:
1
App. Key:
A
Cond. Code:
1
Status:
A
STYLE DESIGNATOR TAP, CIRCUIT SELECTOR style nsn 5930-01-316-1751

Definition Definition of approved item name (AIN): "SWITCH,ROTARY"

A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see switch, sensitive. Excludes relay, rotary; switch, stepping; and switch, telephone (as modified).

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
4.3000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5930-01-316-1751 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
Y
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality Y

The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restrictions or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.