Serving our customers with quality and safety first.
dustproof and moisture resistant and salt spray resistant and vibration resistant
1.217in. ⁓1-7/32"
0.607in.
0.640in.
0.140in.
0.315in.
0.140in.
0.937in.
internal sensor
-65.0 deg fahrenheit and 550.0 deg fahrenheit
bracket and slot and unthreaded hole
hermetically sealed case
increase
two position IN-Line
1 pole, single throw, normally closed, momentary action
tab, solder lug
5.0 amperes resistive load first VOLTAGE2.0 amperes resistive load second VOLTAGE1.0 amperes resistive load third VOLTAGE5.0 amperes resistive load fourth voltage
actuation point not adjustable and deactuation point not adjustable
194.00 actuation point degrees fahrenheit and 176.00 deactuation point degrees fahrenheit
30.0 ac at sea level first VOLTAGE125.0 ac at sea level second VOLTAGE250.0 ac at sea level third VOLTAGE30.0 dc at sea level fourth voltage
gas or liquid
contacts silver
silver
disc w/flange
A switch that is actuated by changes in ambient temperature. Excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. See also control, temperature (as modified) and regulator, temperature (as modified).
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item contains silver.
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.