NSN 5930-01-188-4215 NIIN 011884215 — Pressure Switch

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5930-01-188-4215
5930011884215
Description:
SWITCH,PRESSURE
NSN Assigned:
04-SEP-84
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5930-01-188-4215 Specification Set by the OEM (see RNCC code 3)

Inside Diameter AARX:

0.250in. first CONNECTION0.750in. second connection

Overall Length ABHP:

8.180in. ⁓8-3/16"

Overall Height ABKW:

5.380in.

Overall Width ABMK:

7.060in.

Unthreaded Mounting Hole Diameter AEBV:

0.440in.

Distance Between Mounting Facility Centers AEJN:

5.880in.

Pressure Switch Type AJZC:

differential

Operating Temp Rating AWTN:

-10.0 deg fahrenheit and 185.0 deg fahrenheit

Mounting Method AXGY:

bracket and unthreaded hole

Contact Action Stimulus CQGB:

decrease

Proof Pressure CQJB:

15000.00 pounds per square inch gage

Nominal Thread Size CQJX:

0.250in. first pressure CONNECTION0.750in. second pressure connection ⁓3/4"

Mounting Facility Pattern CQYJ:

two position IN-Line

Nonpile-up Contact Arrangement CRLD:

1 pole, double throw, one position momentary

Terminal Type CSCF:

screw

Contact Load Current Rating CTHF:

6.0 amperes resistive load first voltage and 6.0 amperes inductive load first VOLTAGE3.0 amperes resistive load second voltage and 3.0 amperes inductive load second VOLTAGE1.5 amperes resistive load third voltage and 1.5 amperes inductive load third VOLTAGE1.2 amperes resistive load fourth voltage and 1.2 amperes inductive load fourth VOLTAGE220.0 milliamperes resistive load fifth voltage and 220.0 milliamperes inductive load fifth VOLTAGE110.0 milliamperes resistive load sixth voltage and 110.0 milliamperes inductive load sixth voltage

Contact Adjustability CTYC:

actuation point adjustable

Contact Adjustment Range CTYM:

+90.00/+2900.00 actuation point pounds per square inch gage

Contact Voltage Rating In Volts CTZB:

120.0 ac at sea level first VOLTAGE240.0 ac at sea level second VOLTAGE480.0 ac at sea level third VOLTAGE600.0 ac at sea level fourth VOLTAGE125.0 dc at sea level fifth VOLTAGE250.0 dc at sea level sixth voltage

Pressure Connector Type CTZL:

plain, threaded internal all connections

Frequency In Hertz FREQ:

50.0 first voltage and 60.0 first VOLTAGE50.0 second voltage and 60.0 second VOLTAGE50.0 third voltage and 60.0 third VOLTAGE50.0 fourth voltage and 60.0 fourth voltage

Media For Which Designed MEDA:

gas or liquid

Thread Series Designator THSD:

npt all pressure connection

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
1538-S33-G7
Cage Code:
51918
RNCC:
C
RNVC:
1
DAC:
6
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
9012GCR-2
Cage Code:
56365
RNCC:
3
RNVC:
2
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
9012ADR26
Cage Code:
51918
RNCC:
5
RNVC:
9
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
9012GCR-2
Cage Code:
51918
RNCC:
5
RNVC:
9
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00206
FIIG:
A048B0
Concept No.:
1
App. Key:
D
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "SWITCH,PRESSURE"

A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes baroswitch; switch, pressure-thermostatic; and switch, sensitive.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
20.4000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5930-01-188-4215 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.