NSN 5930-01-087-2664 NIIN 010872664 — Pressure Switch

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5930-01-087-2664
5930010872664
Description:
SWITCH,PRESSURE
NSN Assigned:
14-DEC-79
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5930-01-087-2664 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

4.000in. ⁓4-1/64"

Overall Width ABMK:

2.500in.

Body Diameter ABPM:

1.870in.

Unthreaded Mounting Hole Diameter AEBV:

0.203in.

Distance Between Mounting Facility Centers AEJN:

2.250in.

Pressure Switch Type AJZC:

gage

Operating Temp Rating AWTN:

-30.0 deg fahrenheit and 160.0 deg fahrenheit

Mounting Method AXGY:

bracket and unthreaded hole

Thread Quantity Per Inch CMLP:

18 single pressure connection

Contact Action Stimulus CQGB:

increase

Proof Pressure CQJB:

500.00 pounds per square inch

Nominal Thread Size CQJX:

0.250in. single pressure connection ⁓1/4"

Mounting Facility Pattern CQYJ:

two position IN-Line

Nonpile-up Contact Arrangement CRLD:

1 pole, double throw, one position momentary

Terminal Type CSCF:

connector, receptacle

Contact Load Current Rating CTHF:

5.0 amperes resistive load second voltage and 3.0 amperes inductive load second voltage

Contact Adjustability CTYC:

deactuation point not adjustable and actuation point not adjustable

Contact Stimulus Rating CTYX:

2.25 actuation point pounds per square inch and 12.00 actuation point pounds per square inch and 1.00 deactuation point pounds per square inch and 10.75 deactuation point pounds per square inch

Contact Voltage Rating In Volts CTZB:

28.0 dc at sea level second voltage

Pressure Connector Type CTZL:

swivel nut, double compression, threaded external single connection

Thread Series Designator THSD:

npt single pressure connection

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
5SE01120-1
Cage Code:
28638
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
611GC1
Cage Code:
09049
RNCC:
5
RNVC:
1
DAC:
3
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00206
FIIG:
A048B0
Concept No.:
1
App. Key:
D
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "SWITCH,PRESSURE"

A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes baroswitch; switch, pressure-thermostatic; and switch, sensitive.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.5000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5930-01-087-2664 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.