5930-00-458-9759
5930004589759
Description:
SWITCH,THERMOSTATIC
NSN Assigned:
26-DEC-69
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5930-00-458-9759 Specification Set by the OEM (see RNCC code 3)

Thread Class AAJD:

2a single threaded stud

Thread Length AASA:

0.141in. single threaded stud ⁓9/64"

Overall Height ABKW:

0.578in.

Body Height ADAU:

0.188in.

Overall Diameter ADAV:

0.614in. ⁓5/8"

Temp Sensing Element Type AKBY:

internal sensor

Mounting Method AXGY:

threaded stud

Thread Quantity Per Inch CMLP:

40 single threaded stud

Contact Action Stimulus CQGB:

decrease

Nominal Thread Size CQJX:

0.112in. single threaded stud ⁓1/8"

Nonpile-up Contact Arrangement CRLD:

1 pole, single throw, normally open, momentary action

Terminal Type CSCF:

tab, solder lug

Contact Load Current Rating CTHF:

1.0 amperes resistive load single voltage

Contact Adjustability CTYC:

actuation point not adjustable and deactuation point not adjustable

Contact Stimulus Rating CTYX:

16.00 actuation point degrees fahrenheit and 12.00 deactuation point degrees fahrenheit and 15.00 deactuation point degrees fahrenheit

Contact Voltage Rating In Volts CTZB:

120.0 ac at sea level single voltage

Media For Which Designed MEDA:

gas or liquid

Style Designator STYL:

disc

Thread Series Designator THSD:

unc single threaded stud

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
10681759-3
Cage Code:
18876
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
BD
Status:
A
MSDS:
SADC:
Part Number:
A8663
Cage Code:
05584
RNCC:
5
RNVC:
2
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
3159-22-11
Cage Code:
14604
RNCC:
5
RNVC:
2
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
436-614
Cage Code:
93410
RNCC:
5
RNVC:
9
DAC:
6
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00451
FIIG:
A048B0
Concept No.:
1
App. Key:
F
Cond. Code:
1
Status:
A
STYLE DESIGNATOR DISC style nsn 5930-00-458-9759
STYLE DESIGNATOR DISC style nsn 5930-00-458-9759
STYLE DESIGNATOR DISC style nsn 5930-00-458-9759
STYLE DESIGNATOR DISC style nsn 5930-00-458-9759
STYLE DESIGNATOR DISC style nsn 5930-00-458-9759
STYLE DESIGNATOR DISC style nsn 5930-00-458-9759
STYLE DESIGNATOR DISC style nsn 5930-00-458-9759

Definition Definition of approved item name (AIN): "SWITCH,THERMOSTATIC"

A switch that is actuated by changes in ambient temperature. Excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. See also control, temperature (as modified) and regulator, temperature (as modified).

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5930-00-458-9759 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.