NSN 5930-00-118-8097 NIIN 001188097 — Pressure Switch

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5930-00-118-8097
5930001188097
Description:
SWITCH,PRESSURE
NSN Assigned:
11-OCT-68
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5930-00-118-8097 Specification Set by the OEM (see RNCC code 3)

Inside Diameter AARX:

0.250in. single connection

Overall Length ABHP:

7.250in. ⁓7-1/4"

Overall Height ABKW:

3.500in.

Overall Width ABMK:

6.000in.

Body Length ADAQ:

5.500in.

Body Width ADAT:

3.600in.

Unthreaded Mounting Hole Diameter AEBV:

0.250in.

Longest Horizontal Distance Between Mounting Centers AFDS:

5.750in.

Longest Vertical Distance Between Mounting Centers AFDV:

3.100in.

Pressure Switch Type AJZC:

gage

Operating Temp Rating AWTN:

-30.0 deg fahrenheit and 160.0 deg fahrenheit

Mounting Method AXGY:

bracket and unthreaded hole

Features Provided CBBL:

hermetically sealed case

Thread Quantity Per Inch CMLP:

18 single pressure connection

Contact Action Stimulus CQGB:

increase

Proof Pressure CQJB:

4500.00 pounds per square inch

Nominal Thread Size CQJX:

0.250in. single pressure connection ⁓1/4"

Mounting Facility Pattern CQYJ:

four position rectangular

Nonpile-up Contact Arrangement CRLD:

1 pole, double throw, one position momentary

Sensing Element Burst Pressure CSCC:

500.00 pounds per square inch

Terminal Type CSCF:

connector, receptacle

Contact Load Current Rating CTHF:

4.0 amperes resistive load second voltage

Contact Adjustability CTYC:

deactuation point adjustable and actuation point adjustable

Contact Adjustment Range CTYM:

+50.00/+250.00 actuation point pounds per square inch and +44.00/+226.00 deactuation point pounds per square inch

Contact Adjustment Type CTYS:

internal actuation point screw with scale and internal deactuation point screw with scale

Contact Voltage Rating In Volts CTZB:

480.0 ac at sea level first voltage

Pressure Connector Type CTZL:

double compression, threaded internal single connection

Media For Which Designed MEDA:

gas or liquid

Style Designator STYL:

rectangular w/bracket

Thread Series Designator THSD:

npt single pressure connection

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
64A92B925
Cage Code:
10001
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
604GR3
Cage Code:
09049
RNCC:
5
RNVC:
2
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00206
FIIG:
A048B0
Concept No.:
1
App. Key:
D
Cond. Code:
1
Status:
A
STYLE DESIGNATOR RECTANGULAR W/BRACKET style nsn 5930-00-118-8097
STYLE DESIGNATOR RECTANGULAR W/BRACKET style nsn 5930-00-118-8097
STYLE DESIGNATOR RECTANGULAR W/BRACKET style nsn 5930-00-118-8097
STYLE DESIGNATOR RECTANGULAR W/BRACKET style nsn 5930-00-118-8097
STYLE DESIGNATOR RECTANGULAR W/BRACKET style nsn 5930-00-118-8097
STYLE DESIGNATOR RECTANGULAR W/BRACKET style nsn 5930-00-118-8097

Definition Definition of approved item name (AIN): "SWITCH,PRESSURE"

A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes baroswitch; switch, pressure-thermostatic; and switch, sensitive.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
2.5000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
SPI No.:
SPI Rev.:
SPC Mkg:
99
LVL_A:
E
LVL_B:
Q
LVL_C:
U

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5930-00-118-8097 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.