NSN 5930-00-117-6198 NIIN 001176198 — Liquid Level Switch

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5930-00-117-6198
5930001176198
Description:
SWITCH,LIQUID LEVEL
NSN Assigned:
24-DEC-72
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5930-00-117-6198 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

48.125in. ⁓48-1/8"

Overall Height ABKW:

6.125in.

Overall Width ABMK:

6.812in.

Ac Voltage Rating ACYN:

120.0 volts

Dc Voltage Rating ACYR:

6.0 volts

Frequency Rating ACZB:

60.0 hertz

Actuation Method AFLW:

buoyancy

Electrical Connection Type AGBD:

cable

Internal Battery Accommodation ALSF:

not included

Current Rating At Maximum Rated Voltage APGW:

45.0 milliamperes resistive load

Voltage Rating At Maximum Rated Current APGY:

110.0 volts

Float Quantity AWAE:

2

Operating Temp Rating AWTN:

any acceptable

Mounting Method AXGY:

flange

Mounting Position BBJX:

vertical

Maximum Current Rating BJKC:

90.0 milliamperes resistive load

Contact Arrangement BJKD:

2 single pole n.o. as one float control one for alarm w/2 single pole n.c. contacts

Relay BJKG:

not included

Liquid Type For Which Designed BJKH:

various fuels

Mounting Dimensions BJKP:

4-0.562in. dia.holes equally spaced on a 3.125in.bolt center

Tank Insertion Length BJKQ:

41.500in.

Phase FAAZ:

single

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
34664
Cage Code:
04034
RNCC:
3
RNVC:
2
DAC:
6
RNAAC:
CX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
37187
FIIG:
T109-D
Concept No.:
1
App. Key:
DA
Cond. Code:
2
Status:
A

Definition Definition of approved item name (AIN): "SWITCH,LIQUID LEVEL"

A switch which is actuated by a float or sensing device(s) to control liquid level and/or actuate visual or audible warning systems. Used in conjunction with pumps or valves to transfer liquid from one source to another. It may include a relay controlled by the switch element. Excludes transmitter, liquid quantity.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
1.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5930-00-117-6198 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.