NSN 5925-01-097-0334 NIIN 010970334 — Circuit Breaker

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5925-01-097-0334
5925010970334
Description:
CIRCUIT BREAKER
NSN Assigned:
03-JUL-80
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Coast Guard

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5925-01-097-0334 Specification Set by the OEM (see RNCC code 3)

Body Style AAQL:

rectangular dimensional envelope

Overall Length ABHP:

2.422in. ⁓2-27/64"

Overall Height ABKW:

0.750in.

Overall Width ABMK:

2.000in.

Case Material ADTV:

plastic

End Item Identification AGAV:

d.c. electrical panel onboard 41 ft utb coast guard vessels

Pole Quantity AKPX:

1

Mounting Facility Type And Quantity AXHR:

2 threaded hole

Maximum Continuous Load Current Rating Per Pole CPLM:

15.0 amperes dc single location

Operating Voltage Type And Rating Per Pole In Volts CPRF:

65.0 dc single location

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps CPRG:

1000.0 dc single location

Circuit Protection Type CPRH:

overcurrent single location

Trip Release Method CPRJ:

THERMAL-Magnetic single location

Trip Release Characteristic CPRL:

time delay single location

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent CPRN:

1000.0 single location

Ultimate Trip Time Per Pole In Seconds CPRP:

0.004 single location and 0.025 single location

Reset Method CPRQ:

manual

Main Contact Tripping Mechanism Type CPRR:

trip free

Nominal Thread Size CQJX:

0.156in. ⁓5/32"

Trip Delay Time In Seconds Per Rated Continuous Current CQWN:

51.500 at 125 pct single location and 57.500 at 125 pct single location

Trip Release Ambient Temp Rating CRCF:

40.0 deg celsius single location

Thread Series Designator THSD:

unc

Terminal Type And Quantity TTQY:

6 screw

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
APGX6-3374-3
Cage Code:
81541
RNCC:
3
RNVC:
2
DAC:
6
RNAAC:
XF
Status:
A
MSDS:
SADC:
Part Number:
5925-00-LG3-1516
Cage Code:
06101
RNCC:
5
RNVC:
9
DAC:
6
RNAAC:
XF
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A
BODY STYLE RECTANGULAR DIMENSIONAL ENVELOPE style nsn 5925-01-097-0334

Definition Definition of approved item name (AIN): "CIRCUIT BREAKER"

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

5925-01-097-0334 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.