2.000in.
0.750in.
1.530in.
single pole, double throw
1
15.0 amperes ac all locations
250.0 ac all locations
2000.0 ac all locations
overcurrent all locations
MAGNETIC-Hydraulic all locations
125.0 ac all locations
time delay all locations
125.0 all locations
0.700 all locations and 12.000 all locations
manual
trip free
1 control
series/relay trip all locations
continuous all locations
internal at pole one
0.700 at 125 pct all locations and 12.000 at 125 pct all locations and 0.350 at 150 pct all locations and 7.000 at 150 pct all locations and 0.130 at 200 pct all locations and 3.000 at 200 pct all locations and 0.030 at 400 pct all locations and 1.000 at 400 pct all locations and 0.015 at 600 pct all locations and 0.300 at 600 pct all locations and 0.010 at 800 pct all locations and 0.150 at 800 pct all locations and 0.008 at 1000 pct all locations and 0.100 at 1000 pct all locations
corrosion resistant and moisture resistant and salt water resistant and shock resistant and vibration resistant
quick disconnect, male
1.0 ac
125.0 ac
vde approved; toggle handle color is red - marked with white letters of on/off and i/o; aproximate weight per pole 2.2 ounces; dielectric strength with auxiliary switched terminals 600 volts ac, 60 hertz
50.0 all locations or 60.0 all locations
2 screw
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item does not contain precious metal.
No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.