Serving our customers with quality and safety first.
MULTIPOLE-Single actuator type
6.312in.
2.750in.
3.140in.
plastic
4.620in.
1.380in.
4.620in.
1.375in.
moderately rugged
0.710in.
2
air
4 unthreaded hole
general purpose warehouse
55.314 cubicin.
40.0 amperes ac all locations and 40.0 amperes dc all locations
480.0 ac all locations and 250.0 dc all locations
18000.0 ac all locations and 10000.0 dc all locations
overcurrent all locations
THERMAL-Magnetic all locations
instantaneous all locations and time delay all locations
125.0 all locations
manual
trip free
1 toggle
TRIP-Reset
at pole two
725.000 at 100 pct all locations and 1000.000 at 100 pct all locations and 30.000 at 200 pct all locations and 125.000 at 200 pct all locations and 15.000 at 250 pct all locations and 60.000 at 250 pct all locations and 9.000 at 300 pct all locations and 37.500 at 300 pct all locations and 4.250 at 400 pct all locations and 18.000 at 400 pct all locations and 2.400 at 500 pct all locations and 12.000 at 500 pct all locations and 0.440 at 1000 pct all locations and 2.400 at 1000 pct all locations and 0.590 at 2000 pct all locations
10.0 deg celsius all locations and 50.0 deg celsius all locations
60.0 all locations
4 screw
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Precious metal content is unknown
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.