NSN 5925-01-011-1927 NIIN 010111927 — Circuit Breaker Box

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5925-01-011-1927
5925010111927
Description:
CIRCUIT BREAKER BOX
NSN Assigned:
16-OCT-75
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5925-01-011-1927 Specification Set by the OEM (see RNCC code 3)

Hazardous Locations/environmental Protection ABFE:

general PURPOSE-Nema type 1

Overall Depth ABFY:

5.750in.

Center To Center Distance Between Mounting Facilities Parallel To Width ABKR:

11.000in.

Overall Height ABKW:

28.000in.

Overall Width ABMK:

14.000in.

Unthreaded Mounting Hole Diameter AEBV:

0.219in.

Center To Center Distance Between Mounting Facilities Parallel To Height AEBW:

22.000in.

Standard Mounting Pattern Designator AESL:

4 POINT-Rectangular

Mounting Method AXGY:

unthreaded hole

Main Line Maximum Current Rating In Amps BFYC:

100.0

Circuit Breaker Type And Quantity BGJL:

8 single pole and 6 double pole

Circuit Breaker Current Rating In Amps BGJM:

20.0

Extra Long Reference Number ELRN:

NQOD424M100/NQB526/NQC26S/with 8-20A-1P/6-20A-2P

Material MATT:

steel

Surface Treatment SFTT:

enamel

Style Designator STYL:

rectangular, surface mounting

Reference Number Differentiating Characteristics ZZZY:

as differentiated by extra long reference number

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
NQOD424M100/NQB526/NQC26S/WITH -
Cage Code:
56365
RNCC:
3
RNVC:
1
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
19365
FIIG:
A17600
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A
STYLE DESIGNATOR RECTANGULAR, SURFACE MOUNTING style nsn 5925-01-011-1927
STANDARD MOUNTING PATTERN DESIGNATOR 4 POINT-RECTANGULAR style nsn 5925-01-011-1927

Definition Definition of approved item name (AIN): "CIRCUIT BREAKER BOX"

An enclosure which includes, mounts, and protects one or more circuit breakers. It is designed for and may include a cover and such accessories as mounting hardware, brackets, and conduit fittings. May include terminal boards and/or bus conductors used as a convenience for terminating the circuit breakers. May include handle tie bars. It is usually used as a load center for the protection of certain electrical devices such as water heaters, motors, etc., or as a service center for homes or offices. For boxes which include only switches, jacks, fuseholders, terminals and/or terminal boards or fuseholders, or any combination of these devices, see switch box; jack box; terminal box; and distribution box. For boxes designed to mount and protect but do not include circuit breakers, see circuit breaker box subassembly. See also interconnecting cabinet; panel, power distribution; junction box; and cabinet, electrical equipment.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5925-01-011-1927 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.