NSN 5925-00-814-4088 NIIN 008144088 — Circuit Breaker

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5925-00-814-4088
5925008144088
Description:
CIRCUIT BREAKER
NSN Assigned:
01-JAN-62
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5925-00-814-4088 Specification Set by the OEM (see RNCC code 3)

AAQL:

Body Length ADAQ:

2.484in. and 2.516in.

Body Width ADAT:

0.734in. and 0.766in.

Case Material ADTV:

plastic

Center To Center Distance Between Terminals Parallel To Length AEBP:

1.922in. and 1.953in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Length AEBY:

1.047in. and 1.078in.

Fragility Factor AFJN:

moderately rugged

Boss Height AJEC:

0.109in. and 0.141in.

Mounting Surface To Terminal End Distance AJWX:

2.625in.

Pole Quantity AKPX:

1

Arc Quenching Method APNQ:

magnetic blowout

Mounting Facility Type And Quantity AXHR:

2 threaded hole

Storage Type BBRG:

general purpose warehouse

Thread Quantity Per Inch CMLP:

32

Maximum Continuous Load Current Rating Per Pole CPLM:

2.0 amperes ac single location

Operating Voltage Type And Rating Per Pole In Volts CPRF:

250.0 ac single location

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps CPRG:

1000.0 ac single location

Circuit Protection Type CPRH:

overcurrent single location

Trip Release Method CPRJ:

magnetic single location

Trip Release Characteristic CPRL:

time delay single location

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent CPRN:

150.0 single location

Reset Method CPRQ:

manual

Main Contact Tripping Mechanism Type CPRR:

trip free

Manual Actuator Type And Quantity CPRT:

1 toggle

Actuator Function CPRW:

TRIP-Reset

Actuator Position Designation CPRX:

at pole one

Internal Trip Release Configuration CPSM:

series trip single location

Nominal Thread Size CQJX:

0.138in. ⁓9/64"

Trip Delay Time In Seconds Per Rated Continuous Current CQWN:

0.110 at 200 pct single location and 0.600 at 200 pct single location

Inclosure Protection Type For Which Designed CQXF:

fungus proof and humidity resistant and salt spray proof and shock resistant and vibration resistant

Frequency In Hertz FREQ:

400.0 single location

Unpackaged Unit Weight PKWT:

4.250 ounces

Precious Material And Location PMLC:

contacts and other current carrying surfaces silver

Precious Material PRMT:

silver

Thread Series Designator THSD:

unc

Terminal Type And Quantity TTQY:

2 threaded stud

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
9193105
Cage Code:
18876
RNCC:
3
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
AM12MG6-2-250VAC400C16
Cage Code:
74193
RNCC:
5
RNVC:
9
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00136
FIIG:
A030A0
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "CIRCUIT BREAKER"

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
SPI No.:
SPI Rev.:
SPC Mkg:
99
LVL_A:
E
LVL_B:
Q
LVL_C:
U

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5925-00-814-4088 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
S
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) S

Item contains silver.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
S9E
SOS:
MMAC:
MCC:
Source of Supply (SOS) S9E

Defense supply center columbus, columbus, oh 43218

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.