NSN 5915-00-007-0852 NIIN 000070852 — Band Pass Filter

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5915-00-007-0852
5915000070852
Description:
FILTER,BAND PASS
NSN Assigned:
25-JUN-72
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--
Description

Overall Height: 0.95 inches, Operating Temperature Range: -30 to 80 degrees Celsius.

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5915-00-007-0852 Specification Set by the OEM (see RNCC code 3)

Specified Frequencies Of Discrimination Per Function CQFC:

21.365 megahertz blank and 21.392 megahertz blank and 21.407 megahertz blank and 21.435 megahertz blank

Functional Terminal Type And Quantity CQDW:

1 wire lead ground 3rd function

Insertion Loss At Reference Frequency Per Function In Decibels CQDR:

3 blank

Mounting Facility Type And Quantity AXHR:

3 terminal

Inclosure Type AKNA:

encased

Principal Circuitry Type Per Function AHBL:

crystal blank

Load Impedance Per Function AHAS:

1.6 kilohms blank

Source Impedance Rating Per Function AHAQ:

1.6 kilohms blank

Reference Frequency Per Function AHAJ:

21.4 megahertz blank

Operating Temperature Range AFGA:

-30 to 80 degrees celsius

Body Height ADAU:

up to 0.45in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Length AEBY:

0.192in.

Body Length ADAQ:

up to 0.432in.

Body Width ADAT:

up to 0.185in.

Overall Height ABKW:

0.95in.

Frequency Band Width Per Function CRBB:

21.392 megahertz blank and 21.407 megahertz blank

Discrimination At Specified Frequencies Per Function In Decibels CRBC:

20 blank and 3 blank and 3 blank and 20 blank

Style Designator STYL:

rectangular terminal/terminals on one surface

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
329001-1
Cage Code:
37695
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
2250F
Cage Code:
25120
RNCC:
5
RNVC:
2
DAC:
3
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00209
FIIG:
A047B0
Concept No.:
3
App. Key:
A
Cond. Code:
1
Status:
A
STYLE DESIGNATOR RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE style nsn 5915-00-007-0852
STYLE DESIGNATOR RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE style nsn 5915-00-007-0852
STYLE DESIGNATOR RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE style nsn 5915-00-007-0852

Definition Definition of approved item name (AIN): "FILTER,BAND PASS"

An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See coil (as modified); reactor; capacitor (as modified); and resistor (as modified).

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5915-00-007-0852 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.