NSN 5910-00-191-8532 NIIN 001918532 — Fixed Electrolytic Capacitor

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5910-00-191-8532
5910001918532
Description:
CAPACITOR,FIXED,ELECTROLYTIC
NSN Assigned:
01-JAN-63
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5910-00-191-8532 Specification Set by the OEM (see RNCC code 3)

Body Style AAQL:

w/mtg tabs/flanges, terminal (s) on one surfacew/mtg tabs/flanges, terminal (s) on one surfacew/mtg tabs/flanges, terminal (s) on one surface

Reliability Indicator AARG:

not establishednot establishednot established

Body Length ADAQ:

2.000in.

Body Width ADAT:

2.000in.

Body Height ADAU:

1.125in.

Center To Center Distance Between Terminals Parallel To Length AEBP:

1.000in.

Terminal Height From Body AEBU:

0.188in.

Unthreaded Mounting Hole Diameter AEBV:

0.188in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Length AEBY:

2.375in.

Schematic Diagram Designator AEBZ:

no common or grounded electrode (s)

Anode Type AECE:

plain foil

Electrical Polarization AECQ:

polarized

Mounting Facility Type And Quantity AXHR:

2 unthreaded mounting holes

Features Provided CBBL:

hermetically sealed case

Capacitance Value Per Section CQBQ:

10.000 microfarads single section

Nonderated Operating Temp CQJJ:

-32.0 deg celsius and 90.0 deg celsius

Nonderated Continuous Voltage Rating And Type Per Section CQWM:

450.0 dc single section

Tolerance Range Per Section CRTP:

-10.00/+50.00 percent single section

Case Material CWJK:

metal

Capacitive Electrode Material CWNJ:

aluminum

Terminal Surface Treatment CWSG:

solder

Terminal Type And Quantity TTQY:

2 standoff, solder lug

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
K35J601REV10PT3
Cage Code:
24446
RNCC:
3
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
K35J601REV10PT3
Cage Code:
73773
RNCC:
5
RNVC:
9
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00008
FIIG:
A010B0
Concept No.:
1
App. Key:
C
Cond. Code:
1
Status:
A
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S) style nsn 5910-00-191-8532

Definition Definition of approved item name (AIN): "CAPACITOR,FIXED,ELECTROLYTIC"

A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. it may be a single unit, or consist of two or more fixed units which cannot be separated.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5910-00-191-8532 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
P
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) P

Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.