NSN 5905-01-267-3931 NIIN 012673931 — Nonwire Wound Variable Resistor

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5905-01-267-3931
5905012673931
Description:
RESISTOR,VARIABLE,NONWIRE WOUND,
NSN Assigned:
10-NOV-87
DEMIL:
NO
Shelf Life:
N/A
UOM:
No qup EA
Using Services:
Navy, Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5905-01-267-3931 Specification Set by the OEM (see RNCC code 3)

Section Quantity AAPN:

1

Body Style AAQL:

rectangular w/mounting holes/slots

Reliability Indicator AARG:

established

Reliability Failure Rate Level In Percent AARH:

0.100

Mounting Hole Diameter ABTB:

0.093 in.

Shaft Diameter ABWV:

0.115in.

Shaft Length ABXF:

0.058in.

Body Length ADAQ:

1.250in.

Body Width ADAT:

0.190in.

Body Height ADAU:

0.315in.

Shaft Style AEDX:

round, slotted

Shaft Bearing Type AEDZ:

sleeve

Actuator Type AEFD:

single shaft

Effective Electrical Rotation In Deg Angular Rotation AEFH:

6120.0 and 9720.0

Maximum Starting Torque AEFK:

8.00 INCH-Ounces

Maximum Running Torque AEFL:

8.00 INCH-Ounces

Lateral Distance Between Mounting Hole Centers AGTP:

1.000in.

Mounting Facility Quantity AKPV:

2

Terminal Location APXH:

lower adjacent side two rows

Mounting Method AXGY:

unthreaded hole

Cubic Measure CBME:

0.075 cubicin.

Electrical Resistance Per Section CQCC:

20.0 percent, rated amperes c and better flooring

Rotary Actuator Travel In Angular Deg CQCK:

6120.0 and 9720.0

Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power CQGN:

150.0 single section

Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius CRFJ:

-100.0/+100.0 single section

Power Dissipation Rating Per Section In Watts CRGD:

0.75 7th secondary quality

Resistance Tolerance Per Section In Percent CRSS:

-10.0/+10.0 single section

Actuator Travel Control Feature CRSX:

clutch

Ambient Temp In Deg Celsius Per Section At Full Rated Power CSDH:

85.0 single section

Standard Taper Curve Per Section CSDL:

a single section

Test Data Document TEST:

81349-MIL-R-39035 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Terminal Type And Quantity TTQY:

3 wire lead

Specification/standard Data ZZZK:

81349-MIL-R-39035/1 government specification

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
RJR12FL203P
Cage Code:
81349
RNCC:
2
RNVC:
2
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
MIL-R-39035/1
Cage Code:
81349
RNCC:
4
RNVC:
1
DAC:
E
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
RJR12FL203M
Cage Code:
81349
RNCC:
5
RNVC:
9
DAC:
3
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
37405
FIIG:
A002A0
Concept No.:
1
App. Key:
B
Cond. Code:
1
Status:
A
BODY STYLE RECTANGULAR W/MOUNTING HOLES/SLOTS style nsn 5905-01-267-3931
BODY STYLE RECTANGULAR W/MOUNTING HOLES/SLOTS style nsn 5905-01-267-3931
BODY STYLE RECTANGULAR W/MOUNTING HOLES/SLOTS style nsn 5905-01-267-3931
BODY STYLE RECTANGULAR W/MOUNTING HOLES/SLOTS style nsn 5905-01-267-3931
SHAFT STYLE ROUND, SLOTTED style nsn 5905-01-267-3931

Definition Definition of approved item name (AIN): "RESISTOR,VARIABLE,NONWIRE WOUND,"

A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see resistor, adjustable. For items with step by step variation, see rheostat and resistor, step by step. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see attenuator, variable. Excludes resistor (1), variable, wire wound, nonprecision; resistor (1), variable, nonwire wound precision; and resistor (1), variable, wire wound, precision.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
99
LVL_A:
E
LVL_B:
Q
LVL_C:
U
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

LVL C Code (LVL_C) U

Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) postal regulations, (b) department of transportation regulations, (c) civil air regulations, (d) uniform freight classification rules, (e) national motor freight classification rules, (f) american truckers' association rules, (g) other applicable carriers' rules, (h) military air regulations for dangerous materials. consolidation of shipments. all exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. dangerous goods shall be prepared for shipment according to applicable department of transportation (dot) regulations and international regulations in effect at time of shipment. shipment by parcel post must comply with postal regulations.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5905-01-267-3931 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
S9E
SOS:
MMAC:
MCC:
Source of Supply (SOS) S9E

Defense supply center columbus, columbus, oh 43218

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.