NSN 5905-00-833-8206 NIIN 008338206 — Nonwire Wound Variable Resistor

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5905-00-833-8206
5905008338206
Description:
RESISTOR,VARIABLE,NONWIRE WOUND,
NSN Assigned:
01-JAN-62
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5905-00-833-8206 Specification Set by the OEM (see RNCC code 3)

Section Quantity AAPN:

2

Body Style AAQL:

cylindrical bushing mounted

Reliability Indicator AARG:

not established

Body Diameter ABPM:

1.160 centimeters

Shaft Diameter ABWV:

0.250in.

Shaft Length ABXF:

1.310in.

Mounting Bushing Length ADAP:

0.250in.

Body Length ADAQ:

0.432in.

Undercut Diameter AEDQ:

0.125 in.

Shaft Style AEDX:

round, stepped

Actuator Type AEFD:

dual concentric

Effective Electrical Rotation In Deg Angular Rotation AEFH:

312.0

Maximum Starting Torque AEFK:

8.00 INCH-Ounces

Maximum Running Torque AEFL:

8.00 INCH-Ounces

Maximum Stop Torque AEFM:

192.00 INCH-Ounces

Nonturn Device Location AEFN:

at 9 oclock

Nonturn Device Radius AEFP:

0.531in.

Undercut Length AGQL:

0.430 in.

Screw Thread Diameter AJYN:

0.375in.

Screw Thread Series Designator AJYP:

unef

Screw Thread Quantity Per Inch AJYQ:

32.0

Terminal Location APXH:

radially positioned over less than half the circumference

Mounting Method AXGY:

standard bushing

Electrical Resistance Per Section CQCC:

10.0 percent, rated amperes c and better finish and 2.5 gallons per minute c and better industrial clears

Rotary Actuator Travel In Angular Deg CQCK:

312.0

Resistance Temp Characteristic Range Per Section In Percent CQDB:

+0.0/+7.0 -55 deg celsius 1st section and +0.0/+10.0 -55 deg celsius 2nd section and +0.0/+5.0 -25 deg celsius 2nd section and +0.0/+3.5 -25 deg celsius 1st section and +0.0/+2.0 0 deg celsius 1st section and +0.0/+2.5 0 deg celsius 2nd section and -2.5/+2.5 85 deg celsius 1st section and -3.5/+3.5 85 deg celsius 2nd section and +0.0/+5.5 120 deg celsius 1st section and +0.0/+7.5 120 deg celsius 2nd section and +0.0/+8.5 150 deg celsius 1st section and +0.0/+12.5 150 deg celsius 2nd section

Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power CQGN:

150.0 all sections

Power Dissipation Rating Per Section In Watts CRGD:

3.0 7th secondary at 10'30 oclock

Resistance Tolerance Per Section In Percent CRSS:

-20.0/+20.0 all sections

Actuator Travel Control Feature CRSX:

stops

Ambient Temp In Deg Celsius Per Section At Full Rated Power CSDH:

70.0 all sections

Standard Taper Curve Per Section CSDL:

a 1st section and f 2nd section

Special Features FEAT:

inner shaft flatted 0.280 in. length by 0.080 in. height

Test Data Document TEST:

97942-576R030 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

Terminal Type And Quantity TTQY:

6 tab, solder lug

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
576R030H07
Cage Code:
97942
RNCC:
3
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
576R030H07
Cage Code:
79500
RNCC:
5
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
576R030H07
Cage Code:
97942
RNCC:
3
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
576R030H07
Cage Code:
79500
RNCC:
5
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
576R030H07
Cage Code:
97942
RNCC:
3
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
576R030H07
Cage Code:
79500
RNCC:
5
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
576R030H07
Cage Code:
97942
RNCC:
3
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
576R030H07
Cage Code:
79500
RNCC:
5
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
37405
FIIG:
A002A0
Concept No.:
1
App. Key:
B
Cond. Code:
1
Status:
A
BODY STYLE CYLINDRICAL BUSHING MOUNTED style nsn 5905-00-833-8206
BODY STYLE CYLINDRICAL BUSHING MOUNTED style nsn 5905-00-833-8206
SHAFT STYLE ROUND, STEPPED style nsn 5905-00-833-8206
BODY STYLE CYLINDRICAL BUSHING MOUNTED style nsn 5905-00-833-8206

Definition Definition of approved item name (AIN): "RESISTOR,VARIABLE,NONWIRE WOUND,"

A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see resistor, adjustable. For items with step by step variation, see rheostat and resistor, step by step. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see attenuator, variable. Excludes resistor (1), variable, wire wound, nonprecision; resistor (1), variable, nonwire wound precision; and resistor (1), variable, wire wound, precision.

5905-00-833-8206 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.