NSN 5905-00-152-7306 NIIN 001527306 — Nonind Wire Wound Fixed Resistor

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5905-00-152-7306
5905001527306
Description:
RESISTOR,FIXED,WIRE WOUND,NONIND
NSN Assigned:
06-OCT-71
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5905-00-152-7306 Specification Set by the OEM (see RNCC code 3)

Temp Coefficient Of Resistance In Ppm Per Deg Celsius AAPE:

-50.0/+50.0

Electrical Resistance AAPP:

2.490 kilohms

Resistance Tolerance In Percent AAPQ:

-1.000/+1.000

Ambient Temp In Deg Celsius At Full Rated Power AAQF:

25.0

Ambient Temp In Deg Celsius At Zero Percent Rated Power AAQG:

275.0

Temp Range Of Temp Coefficient In Deg Celsius AAQH:

-55.0/+275.0

Inclosure Method AAQZ:

encapsulated

Terminal Type AARB:

wire lead

Reliability Indicator AARG:

not established

Terminal Length ABJT:

0.312in.

Body Length ADAQ:

0.750in.

Body Width ADAT:

0.500in.

Body Height ADAU:

0.420in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Length AEBY:

0.562in.

Power Dissipation Rating In Watts AEFB:

8.000 free air

Mounting Hole Size BYML:

0.093in.

Style Designator STYL:

axial terminal (s)

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
ALB-10
Cage Code:
54294
RNCC:
5
RNVC:
1
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
HG10
Cage Code:
91637
RNCC:
5
RNVC:
1
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
RE3-2491
Cage Code:
33827
RNCC:
C
RNVC:
1
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
RE3-2491
Cage Code:
08748
RNCC:
3
RNVC:
2
DAC:
A
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
KC1000
Cage Code:
19587
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
3010MB
Cage Code:
00213
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
37404
FIIG:
A001A0
Concept No.:
1
App. Key:
B
Cond. Code:
1
Status:
A
STYLE DESIGNATOR AXIAL TERMINAL (S) style nsn 5905-00-152-7306

Definition Definition of approved item name (AIN): "RESISTOR,FIXED,WIRE WOUND,NONIND"

Inc 37404 reinstated on 010303~a resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The items must have inherent characteristics of inducing little or no self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes suppressor, ignition interference. See also resistor (1), fixed, wire wound, inductive.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5905-00-152-7306 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.