NSN 5905-00-115-8074 NIIN 001158074 — Non Wire Wound Variable Resistor

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5905-00-115-8074
5905001158074
Description:
RESISTOR,VARIABLE,WIRE WOUND,NON
NSN Assigned:
20-SEP-68
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy, Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5905-00-115-8074 Specification Set by the OEM (see RNCC code 3)

Section Quantity AAPN:

1

Body Style AAQL:

rectangular w/mounting holes

Reliability Indicator AARG:

not established

Overall Length ABHP:

0.435in. ⁓7/16"

Terminal Length ABJT:

0.300in.

Overall Height ABKW:

0.690in.

Overall Width ABMK:

0.430in. and 0.470in.

Mounting Hole Diameter ABTB:

0.074in.

Mounting Slot Width ABTD:

0.074in.

Shaft Diameter ABWV:

0.070in.

Shaft Length ABXF:

0.060in.

Body Length ADAQ:

0.375in.

Body Width ADAT:

0.145in. and 0.155in.

Body Height ADAU:

0.360in.

Shaft Style AEDX:

round, slotted

Actuator Type AEFD:

single shaft

Effective Electrical Rotation In Deg Angular Rotation AEFH:

9000.0

Maximum Starting Torque AEFK:

5.00 INCH-Ounces

Center To Center Distance Between Terminals AEHT:

0.190in. and 0.210in.

Lateral Distance Between Mounting Hole Centers AGTP:

0.414in. and 0.424in.

Mounting Facility Quantity AKPV:

3

Terminal Location APXH:

left adjacent side single row

Mounting Method AXGY:

slot and unthreaded hole

Center To Center Distance Between Terminal Rows AYQR:

0.100in.

Electrical Resistance Per Section CQCC:

1.0 kilohms single section

Rotary Actuator Travel In Angular Deg CQCK:

9000.0

Center To Center Distance Between Center Terminal And Outside Terminal CQCM:

0.090in. and 0.110in.

Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power CQGN:

175.0 single section

Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius CRFJ:

-50.0/+50.0 single section

Power Dissipation Rating Per Section In Watts CRGD:

1.0 free air single section

Resistance Tolerance Per Section In Percent CRSS:

-5.0/+5.0 single section

Actuator Travel Control Feature CRSX:

clutch

Ambient Temp In Deg Celsius Per Section At Full Rated Power CSDH:

70.0 single section

Standard Taper Curve Per Section CSDL:

a single section

Test Data Document TEST:

08241-GVL20404-3 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

Terminal Type And Quantity TTQY:

3 pin

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
3290P1-102
Cage Code:
80294
RNCC:
3
RNVC:
2
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
Q317106007
Cage Code:
S3092
RNCC:
5
RNVC:
2
DAC:
1
RNAAC:
ZG
Status:
A
MSDS:
SADC:
Part Number:
99046406
Cage Code:
F8224
RNCC:
5
RNVC:
2
DAC:
3
RNAAC:
ZG
Status:
A
MSDS:
SADC:
Part Number:
99046406
Cage Code:
D2416
RNCC:
5
RNVC:
2
DAC:
9
RNAAC:
ZG
Status:
A
MSDS:
SADC:
Part Number:
202-107HS1K
Cage Code:
0EBU2
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
GVL20404-3
Cage Code:
08241
RNCC:
5
RNVC:
9
DAC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
202-107HS1K
Cage Code:
94271
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
TX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
37406
FIIG:
A002A0
Concept No.:
1
App. Key:
A
Cond. Code:
1
Status:
A
BODY STYLE RECTANGULAR W/MOUNTING HOLES style nsn 5905-00-115-8074
SHAFT STYLE ROUND, SLOTTED style nsn 5905-00-115-8074

Definition Definition of approved item name (AIN): "RESISTOR,VARIABLE,WIRE WOUND,NON"

A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see resistor, adjustable. For items with step by step variation, see rheostat and resistor, step by step. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see attenuator, variable. Excludes resistor (1), variable, nonwire wound, nonprecision; resistor (1), variable, nonwire wound, precision; and resistor (1), variable, wire wound, precision.

5905-00-115-8074 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
S9E
SOS:
MMAC:
MCC:
Source of Supply (SOS) S9E

Defense supply center columbus, columbus, oh 43218

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.