NSN 4140-01-642-2927 NIIN 016422927 — Fan Impeller Guard

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
4140-01-642-2927
4140016422927
Description:
GUARD,FAN IMPELLER
NSN Assigned:
20-FEB-15
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

4140-01-642-2927 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

10.250in. ⁓10-1/4"

Overall Height ABKW:

3.890in.

Overall Width ABMK:

9.418in.

Mounting Method AXGY:

spring clip

Part Name Assigned By Controlling Agency CXCY:

fan guard, egad

Special Features FEAT:

condenser coil and fan motor assembly

Shape SHPE:

rectangular

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
116-00 1P
Cage Code:
59431
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
36295
FIIG:
A505H0
Concept No.:
App. Key:
Cond. Code:
2
Status:
A

Definition Definition of approved item name (AIN): "GUARD,FAN IMPELLER"

A safety device specifically designed to protect or shield a fan impeller from physical damage and/or prevent possible injury to personnel while the fan is in operation. It may consist of a wireguard, screen, grille and the like. Excludes cover, electric fan and grille, metal.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

4140-01-642-2927 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Solicitation History DLA solicitations for NSN 4140-01-642-2927

Solicitation
Ends
Qty
AMSC
Buyer
PR
SMB
Solicitation:
SPE8E718T0861
End Date:
12/11/2017
Qty:
8 Ea
AMSC:
D
Buyer Code:
PEPCA
PR:
0071907378
SMB:
0%
Solicitation:
SPE8E718T0163
End Date:
10/23/2017
Qty:
5 Ea
AMSC:
D
Buyer Code:
PEPCA
PR:
0071189437
SMB:
0%
Solicitation:
SPE8E718T0058
End Date:
10/16/2017
Qty:
1 Ea
AMSC:
D
Buyer Code:
PEPCA
PR:
0071082752
SMB:
0%